Mitsubishi Electric Fresh Master GUF-50RD3 Installation Instructions Manual page 14

City multi series
Hide thumbs Also See for Fresh Master GUF-50RD3:
Table of Contents

Advertisement

I GUF-50
100RD3
TM1, TM2, TM3 shown in dotted lines are field work.
Be sure to connect the grounding wire.
Breakers and controller switches should be provided by the customer.
GREEN/YELLOW
RED
WHITE
GREEN/YELLOW
M2
ORANGE
PINK
BLACK
SUPPLY FAN
GREEN/YELLOW
PINK
BLACK
RED
M1
WHITE
BLUE
ORANGE
EXHAUST FAN
RED
GM
YELLOW
ORANGE
ORANGE
LS
YELLOW
YELLOW
W.S
GRAY
TH1 (OA)
GRAY
WHITE
TH4 (RA)
WHITE
YELLOW
Gas
TH3
YELLOW
piping
PINK
Liquid
TH2
PINK
piping
I NOTE 1. TM1,TM2,TM3 shown in dotted lines are field work.
2. Be sure to connect the grounding wire.
3. Breakers should be provided by the customer.
4. MARK
: indicates terminal block,
I SYMBOL EXPLANATION
Symbol
Name
M1
Fan motor (exhaust)
M2
Fan motor (supply)
C
Capacitor
W.S
Water sensor
TH1
Thermistor (outdoor air temp. detection)
TH2
Thermistor (pipe temp. detection/liquid)
TH3
Thermistor (pipe temp. detection/gas)
TH4
Thermistor (room air temp. detection)
LEV
Electronic linear expansion valve
14
BROWN
CND1
FAN2
PURPLE
SW4
5
PURPLE
YELLOW
YELLOW
C
BLACK
PINK
1
FAN4
C
PINK
FAN1
RED
SW5
WHITE
5
WHITE
ORANGE
1
FAN3
FUSE1
ZNR902
DSA1
7
CN70
DB901
1
6
CNL
X02
1
CN27
BROWN
RED
PURPLE
CN4D
LEV
ORANGE
CN60
PINK
WHITE
CN20
LED3
CN22
LED2
SW2
LED1
SW14
CN29
SW3
SW12
SW11
CN21
: connector,
Symbol
TM1
Terminal block (power supply)
TM2
Terminal block (transmission)
TM3
Terminal block (humidistat, monitor)
SW1
Switch (function selection)
SW2
Switch (capacity code setting)
SW3
Switch (function selection)
SW4
Switch
SW5
Switch
SW11
Switch (1st digit address set)
SW12
Switch (2nd digit address set)
SW14
Switch (branch NO. set)
BROWN
BLUE
CND2
TR
X06
X07
GREEN
/YELLOW
X04
1
CNT
3
CN3T
X05
ZNR901
12
X03
11
10
X08
X09
SW1
I Warning
Before obtaining access to terminals, all supply circuits
must be disconnected.
: board insertion connector or fastening connector of control board.
Name
1, 2
A, B
S
CND1, CND2
X02–X09
TR
GM
LS
LED1
LED2
LED3
POWER SUPPLY
TM1
220-240V ~ 50Hz
L
N
BREAKER(16A)
PE
TM3
Operation monitor output
MAX
MIN
AC240V 1A
AC220V 100mA
9
DC 24V 1A
DC 5V 100mA
Malfunction monitor output
8
MAX
MIN
AC240V 1A
AC220V 100mA
7
DC 24V 1A
DC 5V 100mA
Remote Controller
TM2
<PAR-20MAA>
1
2
M-NET transmissiion cable
A
To Outdoor Unit , BC Controller
Fresh Master
B
M-NET Remote controller
<PAR-F27MEA>
S
Shield wire
Symbol
Name
Remote control terminal
M-NET transmission terminal
Shield
Connector (power supply)
Relay
Transformer
Damper motor
Limit switch
Power supply monitor
MA Remote contoller Power supply monitor
M-NET Power supply monitor
L
N