Operation Flowchart
Combustion is stable
YES
NO
Combustion level can switch into High/Low
(for KBE5L 2-step only)
YES
NO
Smoke comes out
NO
YES
Smoke is continuous
YES
Which color is the smoke?
Black
White
Heater is using in high altitude
YES
MODEL:
NO
NO
gives off black
smoke
KBE5S, KBE5L(2-step)
Possible Cause
Nozzle is clogged
Fuel pump is clogged or defective
Change-over switch connector is loose connection
Change-over switch is defective
Fuel viscosity is increasing
Fuel viscosity is increasing
Nozzle is clogged
Combustion air is insufficient
Oxygen for combustion is low because of high
altitude
PAGE# 4
Remedy