Compressor & Inverter - GE PFSE1N Manual

Table of Contents

Advertisement

Compressor & Inverter
Dead compressor?
• 3 tests to make
(5-10-220)
Communication signal from main
control board J15 enables inverter
output
(4-6 VDC connected)
(11-15 VDC unplugged)
Variable voltage output to
compressor from inverter
Excessive current draw(4amps-stops
briefly, 12 attempts every 12 seconds,
8 minute rest.
Operates between 80VAC and
230VAC
Hz range of 57 Hz to 104 Hz
130
GE Celaya Bottom Freezer
8/11/2008

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pfse5nj

Table of Contents