Carrier ComfortLink 30HXC106 Installation Instructions Manual page 29

Fluid-cooled and condenserless chillers
Hide thumbs Also See for ComfortLink 30HXC106:

Advertisement

UNIT VOLTAGE
Supplied
UNIT
V-Hz
30HXA
(3 Ph)
Min Max
230-60
207
253
208/230-60
187
253
460-60
414
506
161
575-60
518
633
380-60
342
418
380/415-50
342
440
230-50
207
253
230-60
207
253
208/230-60
187
253
460-60
414
506
171
575-60
518
633
380-60
342
418
380/415-50
342
440
230-50
207
253
230-60
207
253
208/230-60
187
253
460-60
414
506
186
575-60
518
633
380-60
342
418
380/415-50
342
440
230-50
207
253
230-60
207
253
208/230-60
187
253
460-60
414
506
206
575-60
518
633
380-60
342
418
380/415/50
342
440
230-50
207
253
230-60
207
253
208/230-60
187
253
460-60
414
506
246
575-60
518
633
380-60
342
418
380/415-50
342
440
230-50
207
253
230-60
207
253
208/230-60
187
253
460-60
414
506
261
575-60
518
633
380-60
342
418
380/415-50
342
440
230-50
207
253
230-60
207
253
208/230-60
187
253
460-60
414
506
271
575-60
518
633
380-60
342
418
380/415-50
342
440
230-50
207
253
FLA
— Full Load Amps
ICF
— Maximum Instantaneous Current Flow during start-up (the
point in the starting sequence where the sum of the LRA for the
start-up compressor, plus the total RLA for all running com-
pressors, plus the total FLA for all running fan motors is at a
maximum)
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Ampacity (for wire sizing)
MOCP — Maximum Overcurrent Protection
RLA
— Rated Load Amps
WD
— Wye-Delta Start
XL
— Across-the-Line Start
*Units with one MCA, MOCP , and fuse size value have one terminal block and
require one power supply. Units with two MCA, MOCP , and fuse values have
2 terminal blocks.
†Wye-delta start is standard. Not available in across-the-line start.
NOTES:
1. Main power must be supplied from a field-supplied fused electrical service
with a (factory- or field-installed) disconnect located in sight from the unit.
2. Control circuit power must be supplied from a separate source through a
field-supplied disconnect (except for 380/415-50 units). An accessory con-
trol transformer may be used to provide control circuit power from the main
unit power supply.
3. Maximum incoming wire size for each terminal block is 500 kcmil.
4. Maximum allowable phase imbalance is: voltage, 2%; amps, 5%.
5. Use copper conductors only.
Table 4B — Unit Electrical Data, 30HXA Units (cont)
No. of
Power
Power
Supply
Supply
MCA
Qty
Conductors
Req'd
Req'd
1
6
605.6
1
6
672.9
1
3
304.0
1
3
242.9
1
3
368.0
1
6
384.9
1
6
635.7
1
6
651.5
1
6
723.9
1
3
327.0
1
3
261.4
1
6
395.9
1
6
413.2
1
6
682.6
1
6
707.9
2
12
437.0/437.0
1
3
355.3
1
3
284.0
1
6
430.2
1
6
452.7
1
6
747.7
2
12
468.6/379.8
2
12
520.6/422.0
1
6
400.1
1
3
319.9
1
6
484.4
1
6
505.2
2
12
486.0/415.4
2
12
592.1/379.8
2
12
657.9/422.0
1
6
461.9
1
3
369.1
1
6
559.2
1
6
586.1
2
12
653.7/415.4
2
12
638.0/379.8
2
12
708.9/422.0
1
6
484.9
1
6
387.6
1
6
387.1
1
6
614.4
2
12
682.6/415.4
2
12
683.6/379.8
2
12
759.6/422.0
1
6
513.2
1
6
410.2
1
6
621.4
1
6
653.9
2
12
747.7/415.4
LEGEND
POWER CIRCUIT*
ICF
MOCP
XL
WD
800
955.3
1000
978.9
450
1281.6
477.6
350
1025.1
382.1
500
1428.0
539.0
500
1398.4
533.4
800
858.3
800
1001.2
1000
1029.9
450
1304.6
500.6
350
1043.6
400.6
500
1455.9
566.9
600
1426.7
561.7
1000
905.2
1000
1057.6
700/700
43.0/743.
500
1332.9
528.9
400
1066.2
423.2
600
1490.2
601.2
600
1466.2
601.2
1000
970.3
700/600
726.8/743.0
800/700
743.0/743.0
500
1377.7
573.7
400
1102.1
459.1
600
1544.4
655.4
700
1518.7
653.7
700/600
771.0/638.0
800/600
955.3/743.0
800/700
978.9/743.0
600
1439.5
635.5
450
1151.3
508.3
700
1619.2
730.2
700
1599.6
734.6
800/700
858.3/638.0
800/600
1001.2/743.0
1000/700
1029.9/743.0
600
1462.5
658.5
500
1169.8
526.8
700
1647.1
758.1
800
1627.9
762.9
1000/700
905.2/638.0
800/600
1046.8/743.0
1000/700
1080.6/743.0
600
1490.8
686.8
500
1192.4
549.4
800
1681.4
792.4
800
1667.4
802.4
1000/700
970.3/638.0
6. The MOCP is calculated as follows:
MOCP = (2.25) (largest RLA) + the sum of the other RLAs. Size the fuse
one size down from the result. The RLAs are listed on the unit nameplate.
7. The recommended fuse size in amps (RFA) is calculated as follows:
RFA = (1.50) (largest RLA) + the sum of the other RLAs. Size the fuse one
size up from the result. The RLAs are listed on the unit nameplate.
Units have the following power wiring terminal blocks and parallel
conductors:
VOLTAGE
208/230
(Sizes 076-171)
208/230
(Sizes 186-271)
460
575
380
230 (Sizes 076-171)
230 (Sizes 186-271)
380/415
#>
CONTROL CIRCUIT
Supplied
Recommended
V-Hz
Fuse Size
(Single Ph)
Min Max
700
115-60
104
800
115-60
104
350
115-60
104
300
115-60
104
450
230-60
207
450
230-50
198
800
230-50
207
800
115-60
104
1000
115-60
104
400
115-60
104
300
115-60
104
450
230-60
207
500
230-50
198
800
230-50
207
800
115-60
104
600/600
115-60
104
400
115-60
104
350
115-60
104
500
230-60
207
600
230-50
198
1000
230-50
207
600/500
115-60
104
600/600
115-60
104
450
115-60
104
400
115-60
104
600
230-60
207
600
230-50
198
600/500
230-50
207
700/500
115-60
104
800/600
115-60
104
600
115-60
104
450
115-60
104
700
230-60
207
700
230-50
198
800/500
230-50
207
800/500
115-60
104
800/600
115-60
104
600
115-60
104
450
115-60
104
700
230-60
207
700
230-50
198
800/500
230-50
207
800/500
115-60
104
1000/600
115-60
104
600
115-60
104
450
115-60
104
700
230-60
207
800
230-50
198
1000/500
230-50
207
TERMINAL BLOCKS
OR NON-FUSED
DISCONNECTS
1
2
1
1
1
1
2
1
MCA
and
MOCP
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
CONDUCTORS
6
6
3
3
3
6
6
3