Error Occurrence History Display - Navien NHB-055 Service Manual

Nhb series condensing boilers
Table of Contents

Advertisement

4.4.9 Error occurrence history display

1. At the <Normal operation mode> or <Error display mode>,
press the [Info] button for over 2 seconds to access the error
history mode.
The most recent error will be displayed first.
2. When the [+] / [-] button is pressed, the error history can be
searched. A total of 10 errors are stored in memory and are
labelled from 0 to 9 with 0 being the most recent error.
3. Whenever the [Mode] button is pressed, the previous error
occurrence time difference (unit time, maximum 9999 hr.) and
the sub error code are toggled and displayed.
4. Pressing the [Reset] button for 5 seconds while in the
<ERROR HISTORY DISPLAY MODE> displays "CLR" and deletes
all the ERROR HISTORY DATA.
5. Press the [Reset] button once to return to the <Normal
operation mode>.
6. If there is no button input for 5 minutes, then the system
automatically returns to the <Normal operation mode>.
40
NHB Service Manual
NOTE
While in <ERROR HISTORY DISPLAY MODE> the first digit
indicates the history of the error with 0 being the most
recent. The remaining 3 digits indicate the error code. If
there is no error history, a "0" will be displayed.
Passed time display: The time between the currently
displayed error and the just previously generated error is
displayed in 1-hr unit.
("0" is displayed if the error code is empty)
Ex) When the most recent error code is 615, the sub error
code is 5, and 24 hours have passed since the error was
generated.
When the Sub Error Code is "0" (i.e., there is no sub error
code), the display is as follows:
Version 1.0