Table 41.
Electrical performance continued
Model
Total
No.
Volts
FLA
208/60/3
79.4
230/60/3
77.4
380-420/50/3
38.9
460/60/3
35.2
575/60/3
27.6
208/60/3
88.4
230/60/3
85
380-420/50/3
42.7
460/60/3
39
GEV
575/60/3
30.6
240
208/60/3
96.4
230/60/3
91.4
380-420/50/3
46.4
460/60/3
42.2
575/60/3
33.4
208/60/3
108.2
230/60/3
104
380-420/50/3
50.9
460/60/3
48.5
575/60/3
38.6
208/60/3
110.2
230/60/3
108.2
380-420/50/3
44.7
460/60/3
46.2
575/60/3
36.8
208/60/3
119.2
230/60/3
115.8
380-420/50/3
48.5
460/60/3
50
GEV
575/60/3
39.8
300
208/60/3
127.2
230/60/3
122.2
380-420/50/3
52.2
460/60/3
53.2
575/60/3
42.6
208/60/3
139
230/60/3
134.8
380-420/50/3
56.7
460/60/3
59.5
575/60/3
47.8
WSHP-SVX01E-EN
Electrical Requirements
Comp
Comp
No. of
RLA
LRA
Compr
Cmp
(ea)
(ea)
es.
MCC
31.70
232.0
2
49.5
31.70
261.0
2
49.5
16.70
133.0
2
26.0
14.10
112.0
2
22.0
11.20
92.0
2
17.5
31.70
232.0
2
49.5
31.70
261.0
2
49.5
16.70
133.0
2
26.0
14.10
112.0
2
22.0
11.20
92.0
2
17.5
31.70
232.0
2
49.5
31.70
261.0
2
49.5
16.70
133.0
2
26.0
14.10
112.0
2
22.0
11.20
92.0
2
17.5
31.70
232.0
2
49.5
31.70
261.0
2
49.5
16.70
133.0
2
26.0
14.10
112.0
2
22.0
11.20
92.0
2
17.5
47.10
245.0
2
66.0
47.10
245.0
2
66.0
19.60
118.0
2
27.5
19.60
125.0
2
27.5
15.80
100.0
2
22.2
47.10
245.0
2
66.0
47.10
245.0
2
66.0
19.60
118.0
2
27.5
19.60
125.0
2
27.5
15.80
100.0
2
22.2
47.10
245.0
2
66.0
47.10
245.0
2
66.0
19.60
118.0
2
27.5
19.60
125.0
2
27.5
15.80
100.0
2
22.2
47.10
245.0
2
66.0
47.10
245.0
2
66.0
19.60
118.0
2
27.5
19.60
125.0
2
27.5
15.80
100.0
2
22.2
Blower
Blower
Fan
Min
Motor
Motor
Motor
Circuit
FLA
HP
Num
Amps
16.00
5
1
14.00
5
1
5.50
3
1
7.00
5
1
5.20
5
1
25.00
7.5
1
21.60
7.5
1
9.30
5
1
10.80
7.5
1
8.20
7.5
1
33.00
10
1
28.00
10
1
13.00
7.5
1
14.00
10
1
11.00
10
1
44.80
15
1
40.60
15
1
17.50
10
1
20.30
15
1
16.20
15
1
16.00
5
1
14.00
5
1
5.50
3
1
7.00
5
1
5.20
5
1
25.00
7.5
1
21.60
7.5
1
9.30
5
1
10.80
7.5
1
8.20
7.5
1
33.00
10
1
28.00
10
1
13.00
7.5
1
14.00
10
1
11.00
10
1
44.80
15
1
40.60
15
1
17.50
10
1
20.30
15
1
16.20
15
1
Max
Overcurrent
Electric
Protective
Heat
Device
kW
87.4
110
85.4
110
43.1
50
38.7
50
30.4
40
96.4
125
93.0
110
46.9
60
42.5
50
33.4
40
104.7
125
99.4
125
50.6
60
45.7
50
36.2
45
119.5
150
114.2
150
55.3
70
53.6
70
42.7
50
122.0
150
120.0
150
49.6
60
51.1
70
40.8
50
131.0
175
127.6
150
53.4
70
54.9
70
43.8
50
139.0
175
134.0
175
57.1
70
58.1
70
46.6
60
150.8
175
146.6
175
61.6
80
64.6
80
51.9
60
Electric
Heat
Amps
75