Rheem HE119-130LP Use And Care Manual page 24

Advantageplus series high efficiency commercial gas water heater
Hide thumbs Also See for HE119-130LP:
Table of Contents

Advertisement

HOT
INTAKE
COLD
EXHAUST
FIGURE 5 - SIDE WALL VENTING
HOT
COLD
Venting Samples
3' TO 4" PVC
REDUCING
3" PVC
COUPLING
MIN. 10'
REQ'D
3" ABS
FLOOR MOUNTED
MIN. 84"
PIPE SUPPORT
REQ'D
3"
4" (SIDE VIEW)
3' TO 4" PVC
REDUCING
3" PVC
INTAKE
COUPLING
MIN. 10'
REQ'D
3" ABS
EXHAUST
MIN. 84"
REQ'D
FLOOR MOUNTED
PIPE SUPPORT
FIGURE 7 - SIDE WALL VENTING USING THE V1000 VENT KIT
3"
MAINTAIN 12" MIN.
(18" MIN. FOR CANADA)
CLEARANCE ABOVE HIGHEST
ANTICIPATED SNOW LEVEL.
MAXIMUM OF 24" ABOVE ROOF
4" PVC
HOT
12"
8" MIN.
COLD
4" PVC
MAX. 125'
EQUIVALENT
FEET OF 4"
COMBUSTION
3' TO 4" PVC REDUCING COUPLING
TO UTILIZE V1000 SIDE WALL VENT TERMINAL
4"
3" (SIDE VIEW)*
24
3" PVC
MIN. 10'
REQ'D
FLOOR MOUNTED
PIPE SUPPORT
FIGURE 6 - VERTICAL ROOF VENTING
3"
4" (FRONT VIEW)
FRESH AIR
FOR
OPTIONAL V1000
VENT KIT
(SIDE VIEW)
V1000 SIDE WALL
VENT KIT
(FRONT VIEW)
EXHAUST
*NOTE: THE ONLY TIME 4" CAN BE REDUCED BACK
TO 3" IS WHEN THE V1000 VENT KIT IS UTILIZED.
4" PVC
3' TO 4" PVC
REDUCING
COUPLING
3" ABS
INTAKE
MIN. 84"
REQ'D
EXHAUST