EMS MX-5004MZ User Manual

EMS MX-5004MZ User Manual

4x1 hdmi 2.0a quad-view video processor with 4k2k60 4:4:4

Advertisement

Quick Links

MX-5004MZ
4x1 HDMI 2.0a Quad-View Video Processor
with 4K2K60 4:4:4
User Manual
rev: 160318

Advertisement

Table of Contents
loading

Summary of Contents for EMS MX-5004MZ

  • Page 1 MX-5004MZ 4x1 HDMI 2.0a Quad-View Video Processor with 4K2K60 4:4:4 User Manual rev: 160318...
  • Page 2: Table Of Contents

    However, like all electronic equipment, the MX-5004MZ should be used with care. Please read and follow the s afety instructions to p rotect y ourself from possible injury and to m inimize the risk of damage to the unit.
  • Page 3: Introduction

    INTRODUCTION The MX-5004MZ provides the 4x1 HDMI 2.0a Quad-View Video Processor with 4K2K60 4:4:4 most flexible and cost effective solution in the market to route high definition video source from any of the four FHD HDMI sources to the remote display at the same time. This solution is well suited for use in digital signage, conference room presentation systems or other similar settings or applications.
  • Page 4: Specifications

    SPECIFICATIONS Model Name MX-5004MZ Technical Role of usage Multiplexer / video processor Background picture update HDCP compliance Input: HDMI 1.4 HDMI compliance Output: HDMI 2.0a Input: HDMI [2.25G to 6.75Gbps] Video bandwidth Output: Single-link 600MHz [18Gbps] Output Video Support Up to 4K2K@60 (4:4:4 8bits)
  • Page 5: Hardware Installation

    HARDWARE INSTALLATION MX-5004MZ as master 1. Connect all sources to HDMI Inputs on the MX-5004MZ. 2. Connect the display to HDMI Output on the MX-5004MZ. 3. Connect the +12V 5A DC power supply to the MX-5004MZ. CONNECTION DIAGRAM...
  • Page 6: Panel Descriptions

    PANEL DESCRIPTIONS MX-5004MZ Front Panel IR Sensor: IR Sensor for receiving the IR commands from IR remote IR Receiver: 3.5mm socket for plugging in the extension cable of IR receiver Rear Panel SOURCE 1-4: HDMI inputs Stereo audio output - L...
  • Page 7: Operation Approach

    OPERATION APPROACH Method A: IR Remote Control Button Function HDMI/DVI mode switch Reserved Reserved Power on/off the device Rotation Window A rotate 90 ° or -90° Label Window label on/off Fast Switch output’s audio Sound channel To set up the background Background picture of window Select 4K2K output...
  • Page 8 Method B: Software Control through RS-232 port / Ethernet port System Requirement and Precautions 1. Whenever power off MX-5004MZ, please stay unpowered at least 5 to 10 seconds to allow power capacitors to discharge. 2. The MX-5004MZ provides software control program which runs under Microsoft Windows 98, 2000, XP, 7, 8 through the interface of RS-232 serial control.
  • Page 9: Connection Status

    Control Interface 1. Connection Status: Show the connect information and status. If users use RS-232 serial Mode to connect device, the graph is . In contrast, the graph of Ethernet is . In addition, if users would like to change the control method, users can click on the button to change.
  • Page 10 (2) Quick Selection We provide 9 default modes and 8 custom modes for you to select. (3) Output Resolution Set the output resolution. If user click the 1080p to 4K2K function, when output resolution is 1920 x 1080 @60Hz, it will upscale the resolution to 4K2K. (4) Save Layout We provide 8 custom layout space for users to save the frequently used scenarios into the flash memory.
  • Page 11 (5) Display Panel In the left part of control interface, user can customize the display mode thru control. The different c olors o f frame r epresent t he di fferent i nput w indows. T he i nformation of coordinate shows the position of input source screen.
  • Page 12 (1) Window settings In t his m ode, us er can adj ust i ndividual di splay ar ea f or s elected i nput s ources. Firstly, user have t o c hoose t he s pecific c hannel A , B , C , or D , w hich ar e presented as i n t he control panel as shown.
  • Page 13 4. EDID (Extended display identification data) (1) Learn EDID from Default Select Default EDID  Select Input  Click ton to learn default EDID.  (2) Learn EDID from File Select input  Click ton to select the EDID file and write it into input ...
  • Page 14 5. System Setting (5) Firmware Update Click button to do firmware update.  The “Firmware update” window shows up as below.  Please select the correct COM port or click “Scan” button to connect device. ...
  • Page 15 Click “update” button to do firmware update.  If you want to change OSD (window label) font, please click “OSD Font Update” and  “update” buttons to change OSD font.
  • Page 16 (5) Factory Reset Click ton to do factory default reset.  The process of default reset will take about 25 seconds.  6. IP Configure User also c an us e t he E thernet to c ontrol t he mixer. F irstly, us er should click on the button button to setup network set.
  • Page 17 7. Info Read the Software and firmware version. *Software/firmware information subject to change without notification. 8. Refresh This function can get all information of the device and update this software state.
  • Page 18: Warranty

    SELLER will N OT be l iable f or di rect, i ndirect, i ncidental, s pecial, o r c onsequential dam ages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. Also, the technical information contained herein regarding the MX-5004MZ features and specifications is subject to change without further notice.