Parameter Table Overview - Midas Mida.Black 8 Installation Instructions Manual

Swimming pool heat pump units
Table of Contents

Advertisement

Available languages

Available languages

2.7 Parameter table overview

Parameter
Definition
Desired water temperature in cooling mode
0
Desired water temperature in heating mode
1
Defrosting cycle
2
Evaporator temperature set point for starting defrosting
3
Evaporator temperature set point for stopping defrosting
4
Maximum duration for defrosting
5
Quantity of system
6
Restart after power failure
7
Type of unit:
0=Cooling only
1=Heating &cooling
8
2=Heating & cooling + Auxiliary heating
3=Heating only
Different working mode of water pump:
0= water pump is always on
9
1 = water pump is only running when the heat
pump is switched on
Desired water temperature in auto mode
10
11
Water temperature difference setting for restarting
Low pressure switch detection:
0 = Low pressure switch will detect after compressor
has been running for 10 min
12
1=Low pressure switch will detect after compressor
has been running for 60 min
2=Low pressure switch will never detect
Actual inlet water temp.
A
b
Actual outlet water temp.
Coil temp. in system 1
C
d
Coil temp. in system 2
Ambient temp.
E
Range
Default
8 37
28℃
8 40℃
28℃
10 90Min
45Min
~ ℃
-30 0
-7℃
2 30℃
13℃
1 12Min
8Min
1 4
1
0 1
1 Yes
0 3
1
0 1
0
8 40
30℃
1 20℃
2℃
0/1/2
0
-9 99
-9 99
-9 99
-9 99
-9 99
12
Remark
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Adjusted
by Technicians
Measured Value
Measured Value
Measured Value
Measured Value
Measured Value

Hide quick links: