Baldor BC140 Installation And Operation Manual page 8

Scr dc motor control
Hide thumbs Also See for BC140:
Table of Contents

Advertisement

CAUTION! Disconnect motor leads (A- and A+) from control before performing a "Leakage
CAUTION! Instantaneously applying the Hi-Pot voltage will cause irreversible damage to the
CAUTION! Suitable for use on a circuit capable of delivering not more than 5,000 RMS
CAUTION! Proper shielding, grounding, and filtering of this product can reduce the emission
CAUTION! The Voltage Select Switch setting must match the actual AC line input voltage.
8
Resistance" test on the motor. Failure to disconnect motor from the control may
result in extensive damage to the control. The control is tested at the factory for
high voltage/leakage resistance as part of Underwriters Laboratories
requirements.
control.
symmetrical short circuit amperes listed here at rated voltage.
of radio frequency interference (RFI) which may adversely affect sensitive
electronic equipment.
Verify that the Voltage Select Switch is in the correct position ("115" position for
115 Volt AC line input and "230" position (factory setting) for 208/230 Volt AC line
input). Do not use the "115V" position for 208/230 Volt AC line input voltage or
damage will occur to the control.