LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON
THE FOLLOWING PAGES:
THE FOLLOWING PAGES:
1. CAUTION:
1. CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE
SAME TYPE FUSE.
FUSE.
F
ATTENTION: POUR UNE PROTECTION CONTINUE LES RISQES D'INCELE N'UTILISER
2. CAUTION:
QUE DES FUSIBLE DE MÊME TYPE.
A
V
RISK OF FIRE-REPLACE FUSE AS MARKED.
Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, first check to see that all components in the power supply circuit are not
defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components
in the power supply circuit to fail.
2. CAUTION:
3. Note:
1. Do not use the part number shown on the drawings for ordering. The correct part number is shown in the
Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, first check to see that all components in the power supply circuit are not
parts list, and may be slightly different or amended since the drawings were prepared.
defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components
2. To maintain original function and reliability of repaired units, use only original replacement parts which are
in the power supply circuit to fail.
listed with their part numbers in the parts list section of the service manual.
3. Note:
4. Voltage indications for PLAY and STOP mode on the schematics are as shown below:
1. Do not use the part number shown on the drawings for ordering. The correct part number is shown in the
parts list, and may be slightly different or amended since the drawings were prepared.
2. To maintain original function and reliability of repaired units, use only original replacement parts which are
listed with their part numbers in the parts list section of the service manual.
4. Voltage indications for PLAY and STOP mode on the schematics are as shown below:
5. How to read converged lines
1-D3
Distinction Area
Line Number
(1 to 3 digits)
5. How to read converged lines
Examples:
1. "1-D3" means that line number "1" goes to the line number
1-D3
"1" of the area "D3".
Distinction Area
2. "1-B1" means that line number "1" goes to the line number
Line Number
"1" of the area "B1".
(1 to 3 digits)
6. Test Point Information
Examples:
1. "1-D3" means that line number "1" goes to the line number
: Indicates a test point with a jumper wire across a hole in the PCB.
"1" of the area "D3".
2. "1-B1" means that line number "1" goes to the line number
: Used to indicate a test point with a component lead on foil side.
"1" of the area "B1".
: Used to indicate a test point with no test pin.
6. Test Point Information
: Used to indicate a test point with a test pin.
: Indicates a test point with a jumper wire across a hole in the PCB.
: Used to indicate a test point with a component lead on foil side.
: Used to indicate a test point with no test pin.
: Used to indicate a test point with a test pin.
This symbol means fast operating fuse.
Ce symbole represente un fusible a fusion rapide.
2
1
5.0
(Unit: Volt)
The same voltage for
both PLAY & STOP modes
1
2
5.0
(Unit: Volt)
The same voltage for
both PLAY & STOP modes
1-10-2
1-11-2
3
PLAY mode
5.0
(2.5)
STOP mode
Indicates that the voltage
is not consistent here.
3
PLAY mode
5.0
(2.5)
STOP mode
3
Indicates that the voltage
is not consistent here.
2
1
3
A
2
1
A
38
1-B1
AREA D3
AREA B1
1-D3
1-B1
AREA D3
B
C
D
AREA B1
1-D3
B
C
D
B1N_SC
B1P_SC