5. Connection Procedure (See Figure 3)
The procedure for connecting the M3T-FLX-80NRA is shown
below.
(1) Mount the NQPACK080RA on the target system.
(2) Attach the YQPACK080RA on the NQPACK080RA.
(3) Secure the four corners of the YQPACK080RA with the
YQ-GUIDE's.
● Do
not
use
the
YQPACK080RA for fixing the YQPACK080RA.
● The screwdriver included with the NQPACK080RA
is used for fixing the HQPACK080RA. Do not use if
for fixing the YQ-GUIDE's.
(4) Attach the M3T-FLX-80NRA on the YQPACK080RA.
(5) Connect the probe
M3T-FLX-80NRA.
6. External Dimensions and a Sample Foot Pattern
Figure 4 External dimensions and a sample foot pattern of the M3T-FLX-80NRA
screws
included
with
tip
of the emulator
the
M3T-FLX-80NRA
YQ-GUIDE (x4)
to
the
YQPACK080RA
NQPACK080RA
80-pin 0.8-mm-pitch
(80P6N-A) foot pattern
Figure 3 Connection procedure of the M3T-FLX-80NRA
(3/4)
Probe of emulation pod
(5)
(4)
(3)
(2)
(1)
: No. 1 pin
Be sure to align the pins.