Remington 494 Operating Instructions Manual page 8

Powder actuated fastening tool
Table of Contents

Advertisement

Safety Precautions
3"
482-38
6.
DO NOT drive power fasteners into concrete less than three times as thick as the intended
fastener penetration, within 3" of the edge, within 3" of another power fastener or within 3" of
a failed power fastener.
WELD
482-40
TOO THIN
G 018
7.
DO NOT drive power fasteners into steel base material less then 3/16" thick, within 2" of a weld,
within 1/2" of the edge or within 1" of another power fastener.
G 018
8.
When fastening into masonry walls, always drive into horizontal mortar joints, never into vertical
mortar joints. BE CAREFUL. A poorly laid joint may permit too much penetration, and/or
unsatisfactory holding power.
;
OPERATING THE TOOL
; ;
1.
ALWAYS hold tool perpendicular to work surface.
1X
3X
3/16" MIN
3"
3"
3"
482-39
1"
1/2"
482-41
8