Priming The Machine; Adjusting Pressure - Edic Galaxy 2000CX-HR Owner's And Operator's Manual

Professional 12 gallon carpet extractor
Table of Contents

Advertisement

PRESSURE RELIEF/POWER PRIME VALVE:
For location, see #8 on page 6 and 7.
CLOSED
OPEN
PRIMING THE PUMP:
This machine is equipped with a PRESSURE RELIEF/
POWER PRIME VALVE. To prime the machine, turn on
the pump and turn the valve to open position ("O") wait
a few seconds until the pump changes pitch and place it
back to the closed position. You may "POWER PRIME"
the pump by following the above steps, placing your hand
over the RECOVERY HOSE/ VACUUM INLET BARB
(#5 on pages 6&7)
RELIEVING PRESSURE:
In the event that you cannot connect or disconnect the
hoses, attachments or accessories to or from the solution
system, you must first relieve the pressure. To do so, Turn
off the pump and turn the PRESSURE RELIEF/POW-
ER PRIME VALVE to the open position ("O") and then
connect or disconnect the attachment. Always place the
Pressure relief valve back to the closed position.
WARNING: DO NOT LEAVE THE MACHINE UNAT-
TENDED WITH THE PRESSURE RELIEF/PRIMING
VALVE OPEN! FLOODING MAY OCCUR. CLOSE
THE VALVE DURING USE TO PREVENT PRESSURE
LOSS. DO NOT USE THE PRIMING VALVE TO REG-
ULATE PRESSURE.
ADJUSTING PRESSURE USING THE
PRESSURE REGULATOR:
Pressure gauge
Pressure regulator
This machine is equipped with a PRESSURE REGU-
LATOR and PRESSURE GAUGE. You may adjust the
pressure between 100PSI and 500PSI. The machine
has been set to the max pressure at the factory. DO
NOT exceed 500PSI. For location, see #9 & #10 on
pages 6 & 7.
TO REDUCE PRESSURE:
1. Turn on the pump. Prime, if necessary.
2. DO NOT SPRAY WHILE ADJUSTING.
3. Turn the PRESSURE REGULATOR count-
er-clockwise and monitor the PRESSURE
GAUGE until you have reached the desired
Pressure.
TO INCREASE PRESSURE:
1. Turn on the pump. Prime, if necessary.
2. DO NOT SPRAY WHILE ADJUSTING.
3. Turn the PRESSURE REGULATOR clockwise
and monitor the PRESSURE GAUGE until you
have reached the desired Pressure.
WARNING: DO NOT EXCEED 500PSI!