Specifications; Battery Installation; Ordering Information - Oakton PCTS5 Operating Manual

Pctstestr 5 pocket tester

Advertisement

Specifications

Range
Resolution
Accuracy
pH
Calibration points
Automatic temperature
compensation (ATC)
0 to 200.0 μS/cm, 0 to 2000 μS/cm,
Range
Resolution
0.1 μS/cm, 1 μS/cm, 0.01 mS/cm
Conductivity
Accuracy
1, 2, or 3 points; auto standard
Calibration points
Range
TDS
TDS factor
Salinity
Range
Range
Temperature
Resolution
Accuracy
Display: LCD with two-color backlight. Blue = measurement mode;
Green = calibration mode
Reading lock: HOLD icon
Power: four AAA batteries (included); >400 hours of
continuous operation
Low-voltage warning:
battery status icon flashes
Auto power-off: tester automatically turns off after 8 minutes
of nonuse
IP rating: IP67 (waterproof), floats on water when sensor cap is on
Dimensions (L x W x H): 7" x 1.5" x 1. 5" (17.8 x 4 x 4 cm)
Weight: 4.7 oz (133 g)

Ordering Information

Model
Product description
PCTS5
PCTSTestr 5 multiparameter pocket tester
Replacement probe for PCTSTestr 5
Additional probes compatible with PCTSTestr 5 tester
Standard glass bulb pH probe
Flat pH probe for surface testing
Spear-tip pH probe for semisolids and solids
Conductivity probe
7
10
Probe Replacement
Screw off the probe/sensor ring, unplug the probe, plug in the new
–2.00 to 16.00 pH
replacement probe (pay attention to the probe's position), and
0.01 pH
rescrew on the sensor ring.
±0.01 pH ±1 digit
1, 2, or 3 points;

Battery Installation

auto buffer recognition
The tester uses four AAA batteries. Please install batteries according to
32 to 122°F (0 to 50°C)
the following steps. Note the correct direction of battery installation: the
positive side (+) of every single battery must face up. Incorrect installa-
0 to 20.00 mS/cm
tion of batteries will cause damage to the tester and create a potential
hazard.
±1% full-scale
recognition
0.1 ppm to 10.00 ppt
0.40 to 1.00
0 to 10.00 ppt
1
32 to 122°F (0 to 50°C)
0.1°C/°F
±0.9°F (0.5°C)
1. Pull the battery cap up.
2. Slide the battery cap along the direction of arrow.
3. Open the battery cap.
4. Insert the batteries (ALL POSITIVE SIDES FACING UP).
5. Close the battery cap.
6. Slide and lock the battery cap along the direction of arrow.
7. Fit the tester's cap while making sure to push all the way
down. The tester's waterproof design may be compromised if
the cap is not fitted correctly.
Catalog
number
35634-60
35634-62
35634-18
35634-48
35634-56
35634-44
4 x AAA Batteries
2
5
+
+
_
_
4
+
+
3
_
6
_
8
11
Warranty
We warrant this instrument to be free from defects in material and
workmanship and agrees to repair or replace free of charge, at
option of Oakton Instruments, any malfunctioned or damaged prod-
uct attributable to responsibility of Oakton Instruments, for a period
of two years from the delivery (a six-month limited warranty applies
to sensors). This warranty does not apply to defects resulting from
actions such as misuse (violation of the instructions in this manual
or operations in the manner not specified in this manual), improper
maintenance, and unauthorized repairs. Warranty period is the time
limit to provide free service for the products purchased by custom-
ers, not the service life of the tester or probe.
Oakton Instruments reserves the right to update the information in
this manual without giving notice in advance.
7
1065O101_MAN_PCTS5_35634-60
9
12
www.4oakton.com
March 2018