Technical Specifications - Antelope Orion32+ Owner's Manual

32-channel ad/da interface with afc clocking technology
Table of Contents

Advertisement

● Check what clocking mode you are in. Are you receiving the clock signal from the source?
● Check that the relevant lock light on the control panel of the Orion32+ is lit up.
● Try a different cable and another source if available.
● Check the routing on the control panel. Have you routed the signal path correctly?
● If you have routed signals to the routing mixer, check their corresponding fader is up.
● Check the relevant peak meters of the control panel by selecting them in the drop down
menu to see if the relevant signal is being received or is being outputted.
DAW
● What buffer size is your DAW set to?
If it is significantly low i.e. lower than 128 samples in your buffer size, try increasing it.
Try increasing the buffer size from the Orion32+ control panel (Windows Only)
Have you checked the input and output routing is correct in your DAW?
● Is the Orion32+ device selected in the relevant sound card section of the DAW's preferences?
If the Orion32+ doesn't show up in you DAW, first try unplugging and plugging back the
Thunderbolt
install the firmware, drivers and control panel for the Orion32+.

11. Technical Specifications

Inputs:
Analog:
Digital:
Word Clock:
Atomic Clock:
Outputs:
Analog:
Digital:
Word Clock:
Thunderbolt
:
TM
cable (or the USB cable), then restarting your Computer and finally re-
TM
4 x D-SUB 25 (32 channels), +20 dBu max, 11.2 kOhms
1 x Fiber Optic MADI
2 x ADAT
1 x S/PDIF
1 x Input @ 75 Ohms 3Vpp on BNC 32 – 192kHz
1 x 10M Input @ 75 Ohms 1Vpp on BNC
4 x D-SUB 25 (32 channels), +20dBu, 56 Ohms
2 x Monitor Outs on TRS ¼ Jacks
1 x Fiber Optic MADI
2 x ADAT
1 x S/PDIF
2 x Outputs @ 75 Ohms 3Vpp on BNC 32 - 192kHz
USB I/O:
USB 2.0 Hi-Speed; Data stream up to 480 Mbits/192kHz,
32 channels I/O, Type B
1 x Thunderbolt
TM
20