  • Page 1 IP1639EN Ditec OBBI Technical manual Swing gates automation (Original instruction) www.ditecentrematic.com...
  • Page 3: Table Of Contents

    Index Subject Page General safety precautions Declaration of incorporation of partly completed machinery Machinery Directive Technical specifications Operating instructions Standard installation Geared motor references Installation Preliminary checks Geared motor installation Electrical connections OBBI3BFCH limit switch adjustment Ordinary maintenance program User instructions Caption This symbol indicates instructions or notes regarding safety, to which special atten- tion must be paid.
  • Page 4: General Safety Precautions

    1. General safety precautions This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed in ac- cordance with Good Working Methods and in compliance with the present standards. Read the instructions carefully before installing the product. Bad installation could be dangerous.
  • Page 5: Declaration Of Incorporation Of Partly Completed Machinery

    (Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Land- skrona, Sweden, declares that the automation for Ditec OBBI type swing gate: - has been constructed to be installed on a manual door to construct a machine pursuant to the Directive 2006/42/EC.
  • Page 6: Technical Specifications

    3. Technical specifications Ditec OBBI3BH Ditec OBBI3BFCH Power supply 24 V= 24 V= Absorption Thrust 1500 N 1500 N Max run 350 mm 350 mm Opening time 25 s / 90° 25 s / 90° Service class 3 - FREQUENT...
  • Page 7: Standard Installation

    Flashing light XEL5 Key selector GOL4M Codified via radio control keyboard LAB9 Magnetic loop detection device for traffic monitoring OBBI3BH Right geared motor OBBI3BFCH Right geared motor with limit switch OBBI3BH Left geared motor OBBI3BFCH Left geared motor with limit switch...
  • Page 8: Geared Motor References

    5. Geared motor references Ø8,5 Ø12 Ø12 Ref. Code Description Key release Casing Draft tube Tube cover Closing plug Tail bracket Head bracket Cable guide sheat hooking bracket...
  • Page 9: Installation

    6. Installation The given operating and performance features can only be guaranteed with the use of ENTREMATIC accessories and safety devices. Unless otherwise specified, all measurements are expressed in mm. 6.1 Preliminary checks Check that the structure is sufficiently rugged and that the hinge pivots are properly lubricated.
  • Page 10 If the gearmotor opening direction needs to be modified, proceed as shown in the figure (example of motor transformation with opening direction from right to left). blue brown Loosen the motor fastening screws. Extract the motor and the re- ducer cap and unthread the motor cable.
  • Page 11 Fix the tail bracket [14], respecting measurements [A] and [B] on the basis of the desired opening angle [D]. On the tail bracket there are holes that facilitate the assembly operation. Fix the piston to the rear bracket [14] with the pin [F] supplied. Extend the haulage tube completely [11] to its maximum length, then shorten it by approximately 20 mm.
  • Page 12 Assemble the tube cover [12] with the cap [13] and seal, and fix it with the screws [H] supplied. Pay attention to the insertion direction. The slits on the closing cap [13] must be on the lower part in order to help the water to come out. Assemble the casing [10], fixing it with the screw [N], paying attention to the positioning of the cable.
  • Page 13: Electrical Connections

    The gearmotors OBB13BH-OBB13BFCH can be connected to the E2HOB control panel. The electrical wiring and the start-up of the gearmotors OBBI3BH and OBBI3BFCH are shown in figure and in the installation manuals of the E2H control panel.
  • Page 14: Obbi3Bfch Limit Switch Adjustment

    7.1 OBBI3BFCH limit switch adjustment The OBBI3BFCH geared motor is fitted with magnetic limit switches. Adjust the limit switches in order to obtain the correct opening and closing of the automation, as indicated in figure. dima regolazione finecorsa limit switch adjusting template finecorsa di chiusura closing limit switch finecorsa di apertura...
  • Page 15: Ordinary Maintenance Program

    8 . Routine maintenance plan Perform the following operations and checks every 6 months according to intensity of use of the automation. Disconnect the 230 V~ power supply and batteries if present: Clean and lubricate, using neutral grease, the turning pins, the hinges of the gate and the drive screw Check that fastening points are properly tightened.
  • Page 17: User Instructions

    Operating instructions General safety precautions These precautions are an integral and essential part of the product and must be sup- plied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed.
  • Page 18 For any problems and/or information, contact the support service. Installer's stamp Operator Date of intervention Technician's signature Customer's signature Intervention performed Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.ditecentrematic.com...
  • Page 19 All the rights concerning this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been drawn up with the greatest care, Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication.
  • Page 20 Entrematic Group AB Lodjursgatan 10 SE-261 44 Landskrona Sweden www.ditecentrematic.com...