Download Print this page

Toshiba TOSVERT VF-MB1 Instruction Manual page 6

Traverse control for textile machines
Hide thumbs Also See for TOSVERT VF-MB1:

Advertisement

The traverse operation signal can be sent from inverter to external devices.
Assign the function No. 124 / 125 [inverse] (traverse in progress) and 126 / 127 [inverse] (traverse
deceleration in progress) to the output terminals.
Output terminal selection parameter: f130 to f138
Example:
Output the raverse in progress signal from the RY-RC terminal.
Output the traverse deceleration in progress signal from the OUT terminal.
Title
Output terminal selection 1A
(RY-RC)
Output terminal selection 2A
(OUT)
Reference
frequency
Traverse in progress
(RY-RC)
Traverse deceleration in progress
(OUT-NO)
Function
Output frequency (Hz)
Fig. 5 Traverse output signals
Adjustment range
~
~
During operation
OFF
ON
5
E6581750
Example of setting
(Traverse in progress)
(Traverse deceleration
in progress)
Time (sec.)

Advertisement