Vent Piping Guidelines - Lennox EL195UH040NE36B Installation Instructions And Use

Elite el195uhne series gas furnace, upflow / horizontal air discharge
Hide thumbs Also See for EL195UH040NE36B:
Table of Contents

Advertisement

REPLACING FURNACE THAT WAS PART OF A
COMMON VENT SYSTEM
CHIMNEY
OR GAS
VENT
(Check sizing
for water
heater only)
FURNACE
(Replaced)
If replacing a furnace which was
commonly vented with another gas appliance, the size
of the existing vent pipe for that gas appliance must be
checked. Without the heat of the original furnace flue
products, the existing vent pipe is probably oversized for
the single water heater or other appliance. The vent
should be checked for proper draw with the remaining
appliance.
Figure 22
Exhaust Piping (Figures 23, 26 and 27)
The vent adapter must be attached to the exhaust cou-
pling on the furnace top panel. Use provided bands. See
steps below.
1 - Remove the caution tag from vent adapter.
2 - Fully insert vent adapter with both bands loosely
attached on the furnace exhaust coupling
3 - Insert PVC exhaust pipe through vent adapter. Ensure
vent pipe is fully seated into exhaust coupling.
4 - Tighten both top and bottom bands to 40in-lbs.
NOTE - PVC / ABS / NORYL transition solvent cement
WELD-ON 4052 (or equivalent) must be used for con-
necting PVC exhaust pipe to NORYL furnace exhaust
coupling.
Route piping to outside of structure. Continue with instal-
lation following instructions given in piping termination
section.
CAUTION
Do not discharge exhaust into an existing stack or
stack that also serves another gas appliance. If vertical
discharge through an existing unused stack is required,
insert PVC pipe inside the stack until the end is even
with the top or outlet end of the metal stack.
CAUTION
The exhaust vent pipe operates under positive pressure
and must be completely sealed to prevent leakage of
combustion products into the living space.
WATER
HEATER
OPENINGS
(To Adjacent
Room)
Page 17
Vent Adaptor To Exhaust Coupling
PVC
Exhaust Pipe
Top Band
(torque to 40in-lbs)
Bottom Band
(torque to 40in-lbs)
Figure 23

Vent Piping Guidelines

NOTE - Lennox has approved the use of DuraVent® and
Centrotherm manufactured vent pipe and terminations as
an option to PVC. When using the PolyPro® by DuraVent
or InnoFlue® by Centrotherm venting system the vent
pipe requirements stated in the unit installation instruc-
tion – minimum & maximum vent lengths, termination
clearances, etc. – apply and must be followed. Follow the
instructions provided with PoyPro by DuraVent and Inno-
Flue by Centrotherm venting system for assembly or if re-
quirements are more restrictive. The PolyPro by Duravent
and InnoFlue by Centrotherm venting system must also
follow the uninsulated and unconditioned space criteria
listed in table 7.
The EL195UHNE can be installed as either a Non-Di-
rect Vent or a Direct Vent gas central furnace.
NOTE - In Non-Direct Vent installations, combustion air
is taken from indoors and flue gases are discharged out-
doors. In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors.
Intake and exhaust pipe sizing -- Size pipe according to
tables 4 and 5. Count all elbows inside and outside the
home. Table 4 lists the minimum vent pipe lengths per-
mitted. Table 5 lists the maximum pipe lengths permitted.
Regardless of the diameter of pipe used, the standard
roof and wall terminations described in section Exhaust
Piping Terminations should be used. Exhaust vent termi-
nation pipe is sized to optimize the velocity of the exhaust
gas as it exits the termination. Refer to table 8.
In some applications which permit the use of several dif-
ferent sizes of vent pipe, a combination vent pipe may be
used. Contact Lennox' Application Department for assis-
tance in sizing vent pipe in these applications.
Vent
Adaptor
Furnace
Exhaust Coupling
Furnace