a.
Rotate the touch control board upside down (1).
b.
Lift the Mylar from on top of the connectors on the touch control board (2).
c.
Disconnect the two ribbon cables (3)(4) from the board.
d.
Disconnect the touch cable (5).
e.
Lift the Mylar on the display panel cable (6), and then disconnect the cable from the panel (7).
The touch control board, cable, and display panel are available in the Touch Panel Kit using spare
part number L30424-001.
72
Chapter 6 Removal and replacement procedures for Authorized Service Provider parts