DeFelsko PosiTector 6000 Manual
Hide thumbs Also See for PosiTector 6000:

Advertisement

Introduction
Introduction
Principles of Operation
F probes use the magnetic principle to measure the thickness
of non-magnetic coatings on ferrous metals.
N probes use the eddy current principle to measure the
thickness of non-conductive coatings on non-ferrous metals.
FN probes combine the full abilities of both the "F" and "N"
probes.
NOTE:
Throughout this manual, the
information about the particular topic or feature is available on our
website. Go to: www.defelsko.com/manuals
Certification
All probes include a Certificate of Calibration. For organizations
with re-certification requirements, gages may be returned at
regular intervals for calibration.
customers establish gage calibration intervals based upon their
own experience and work environment. Based on our product
knowledge, data and customer feedback, a one year calibration
interval from either the date of calibration, date of purchase, or
date of receipt is a typical starting point.
Wrist Strap
We recommend attaching and wearing the
supplied wrist strap.
Plastic Lens Shield
The LCD is covered with a thin plastic film for protection against
fingerprints and other marks during shipment. This film, while
usually removed before using the instrument, can be left in place
to protect against paint overspray. Replacements can be
purchased.
W
symbol indicates more
DeFelsko recommends that
1
2
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PosiTector 6000 and is the answer not in the manual?

Questions and answers

Summary of Contents for DeFelsko PosiTector 6000

  • Page 1 Throughout this manual, the symbol indicates more information about the particular topic or feature is available on our website. Go to: www.defelsko.com/manuals Certification All probes include a Certificate of Calibration. For organizations with re-certification requirements, gages may be returned at regular intervals for calibration.
  • Page 2: Operation Overview

    Operation Overview Operation Overview The PosiTector 6000 powers-up when the center navigation button is pressed. To preserve battery life, the Gage powers-down after approximately 5 minutes of no activity. All settings are retained. 1.Remove red protective rubber cap (if supplied) from probe.
  • Page 3: Menu Operation

    Menu Operation Menu Operation Gage functions are menu controlled. To access the Menu, turn the Gage on, then press the center navigation button. Memory Statistics Some buttons have a tick box to their Cal Settings right to indicate current status. An empty box indicates that feature is not active.
  • Page 4 NOTE: symbol disappears whenever a calibration adjustment is made to the Gage. The PosiTector 6000 is factory calibrated and performs an automatic self-check each time it takes a measurement. For many applications, no further adjustment is necessary after a Reset (pg.16). Just check ZERO on the uncoated substrate, then...
  • Page 5 Sometimes Gage readings can be influenced by changes in sub- strate shape, composition, surface roughness or by measuring in a different location on the part. This is why Calibration Adjustments are made possible. 1- or 2-point Calibration Adjustments may be performed if readings are not falling within the expected range of thickness for the application being measured.
  • Page 6 Zero 1.Select the Zero menu option. 2.Press (+) to select the number of readings to be used to obtain an average, typically 3 to 10 readings. The greater the variation between readings, the more readings should be taken to obtain an average.
  • Page 7 2-point Calibration Adjustment Preferred method for very unusual substrate materials, shapes or conditions. Provides greater accuracy within a limited, defined range. This method requires taking two readings at known thickness values: a thin value (often zero) and a thicker value. These values should be on either side of the thickness range to be measured.
  • Page 8: Calibration Memory

    Then, if you return to that part, the corresponding calibration setting can be restored. A “setting” is any calibration adjustment. The PosiTector 6000 always displays the current calibration setting (ex. Cal 3) in the upper right corner of the display.
  • Page 9: Memory Management

    Memory Management Memory Management Memory The PosiTector 6000 can record measurements in memory for printing, transfer to a computer or synchronizing with PosiTector.net. Readings are time-stamped as they are taken. Standard models store up to 250 readings in one group. The...
  • Page 10 can be accumulated for them. Batch 2 contains the statistics for B2s1 and B2s2. # of sub-batches in current batch σ 71.3 current batch current sub-batch # readings in current σ 72.4 sub-batch ↨ statistics (see pg. 13) current reading microns Display (appears only if a batch is currently open)
  • Page 11 Delete Removes a batch or sub-batch completely from memory. The name is deleted and all measurements are erased. Sub-batches can be deleted individually. To delete all related sub-batches, simply delete the top-level batch. View Lists all readings onto the display from the current or most recently used batch or sub-batch.
  • Page 12: Statistics Menu

    Statistics Menu Statistics Menu ü Statistics When selected, a icon and statistical summary will appear on the display. Mean Standard Deviation (average) # of measurements σ 49.8 Minimum ↨ Maximum measurement measurement Last reading Statistics Icon microns Remove the last measurement by pressing the (-) button. Press (+) to clear statistics.
  • Page 13: Connect Menu

    Connect Menu Connect Menu Connect Sync Now Immediately initiates synchronization with PosiTector.net when connected (USB or Bluetooth) to an internet connected PC run- ning PosiTector Desktop Manager (pg.4). ü Auto Sync Allows the Gage to automatically synchronize with PosiTector.net when connected (USB or Bluetooth) to an internet connected PC running PosiTector Desktop Manager (pg.4).
  • Page 14 NOTE: When connected, power is supplied through the USB cable. The batteries are not used and the base unit will not automatically power down. If rechargeable (NiMH) batteries are installed, the Gage will trickle charge the batteries. Bluetooth (Advanced models only) Allows individual readings to be sent to a computer or compatible handheld device as they are taken using Bluetooth wireless technology.
  • Page 15: Setup Menu

    Setup Menu Setup Menu Setup Reset Reset restores factory settings and returns the Gage to a known, out-of-the-box condition. It is handy when settings have been changed, if the Gage behaves unusually, or if a calibration adjustment is not possible. The following occurs: - all batches are closed and stored measurements, images and batch names are erased.
  • Page 16 Gage Info Displays the Gage model number, serial number, software packages, PosiTector.net registration key and the amount of remaining memory for storage of readings. NOTE: For security purposes, the registration key is required to add the Gage to your PosiTector.net account. ü...
  • Page 17 A proper selection calibrates the battery state indicator icon for the battery type. No damage will occur if the wrong battery type is selected. NOTE: DeFelsko recommends the use of eneloop (NiMH) rechargeable batteries. Units Converts the display from inch to metric or vice versa. Stored measurements in memory are not converted.
  • Page 18 Probes Probes Do this... Not this!
  • Page 19 Gage has automatically powered- down. Battery performance decreases at low temperatures. eneloop Batteries (available option) DeFelsko recommends the use of eneloop (NiMH) rechargeable batteries. eneloop batteries combine the advantages of rechargeable batteries and disposable (Alkaline) batteries. They discharge very slowly and can be stored for long periods without having self discharge concerns.
  • Page 20: Troubleshooting

    Gage, probe, your company name, company contact, tele- phone number and fax number or email address. Website: www.defelsko.com/support Available Options Available Options A variety of accessories are available to help you get the most from your PosiTector 6000 coating thickness gage.
  • Page 21 Other brand or product names are trademarks or registered trademarks of their respective holders. Every effort has been made to ensure that the information in this manual is accurate. DeFelsko is not responsible for printing or clerical errors. Distributed by: ABQ Industrial LP USA Tel: +1 (281) 516-9292 / (888) 275-5772 eFax: +1 (866) 234-0451 Web: https://www.abqindustrial.net E-mail: info@abqindustrial.net...