Fieldpiece
Swivel
Clamp
Meter
OPERATOR'S
MANUAL
Model SC54
01
Specifications
Display: 10000 count display with backlight
Overrange: (OL) or (-OL) is displayed
Measurement rate: 2 times per second, nominal
Zero: Automatic
Operating environment: 32°F to 122°F (0°C to 50°C) at <70%
relative humidity
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
(with battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to
18°C (32°F to 64°F), 28°C to 50° C(82°F to 122°F)]
APO (Auto Power Off): Approx. 30 minutes
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life: 100 hours typical alkaline
Low battery indication: Battery icon will be empty (
). "batt"
displays along with a continuous beep when the battery voltage
drops below the operating level. Meter shuts off in 5 seconds.
Dimensions: 258.3mm(H) x 71.2mm(W) x 42.7mm(D)
Weight: Approx. 278g including battery
Altitude: 6562 feet (2000m)
Overload protection: 600VDC or 600VAC rms unless otherwise
stated in the individual test sections.
Test leads: Shall use UL listed test leads complied UL61010-031
rated CATIII 600V or above.
06
Quick Start
1. For electrical testing, connect test leads to
"COM" and "+" jacks. For temperature testing,
remove test leads and slide TEMP switch to
the right.
2. Rotate the dial to your desired function. Press
SEL to cycle through the parameters within
the switch position.
3. Connect to test points and read measurement
on display.
Certifications
UL 61010-1, Second Edition
IEC/EN61010-1
IEC/EN61010-2-032
EMC EN61326-1
C-Tick (N22675)
WEEE
CATIII 600V, class II and pollution degree 2
indoor use comply with CE, RoHS compliant.
02
Functions
Voltage AC (VAC) (50Hz-400Hz)
Test power lines (120, 220, 480), test 24V going to controls, and
test for transformer failure.
Ranges: 0 to 600V Resolution: 0.1V
Accuracy: ±(1.0% + 5 dgts) 50-100Hz
±(6%+5 dgts) 100-400Hz
True RMS: Yes Crest factor: ≤ 3
Input impedance: 1MΩ
Voltage DC (VDC)
Select VDC to measure DC voltage.
Ranges: 0 to 600V
Accuracy: ±(1.0% + 5 dgts) on 600V range
Resolution: 0.1V Input impedance: 1MΩ
MilliVolt DC (mVDC)
Select the mVDC range to display measurements from any
Fieldpiece accessory head. See Modular Expandability section on
reverse page for more details.
Ranges: 1000mV and 10000mV
Accuracy: ±(0.5% + 5 dgts)
Resolution: 0.1mV or 1mV Input impedance: 1MΩ
07
Description
Your SC54 is a swivel clamp meter specially
designed for the HVACR technician. The swivel
on the SC54 allows you to get a good viewing
angle on the display while taking amperage
readings through the clamp, regardless of the
wire orientation. The SC54 has the functions
SC56
you want as an HVACR technician.
Get fast manual ranging performance on an
HOLD
O
Hz
easy to use auto-ranging clamp meter.
F
A
AC
MFD
F
V
AC
V
DC
%
NCV
Hz
The SC54 is compatible with Fieldpiece
°C
°F
INRUSH
accessory heads allowing you to measure many
MFD
WIRELESS ENABLED
parameters on the SC54 display.
%
Hz
°C
°F
SC57
SC57
The bright blue backlight
makes it easier
SEL
to use in any lighting condition. True RMS helps
you take more accurate voltage and amperage
O
F
readings on variable frequency drives.
F
The unique temperature circuit allows the
TRUE RMS
AUTO OFF
30V
K-TYPE
MAX
TEMP
SC54 to get accurate temperature readings
CAT III
600V
faster when moving from a rooftop to a freezer.
The easily accessible field calibration allows
you to calibrate the temperature on your SC54
SEL
SYNC
without hassle.
SC56
TRUE RMS
30V
MAX
O
Hz
F
A
AC
MFD
F
V
AC
V
DC
%
NCV
Hz
°C
°F
TRUE RMS
AUTO OFF
03
30V
MAX
K-TYPE
TEMP
CAT III
SEL
600V
O
F
F
TRUE RMS
AUTO OFF
30V
K-TYPE
MAX
TEMP
CAT III
600V
O
F
F
O
F
F
ON
LCD X
100
Air Velocity
LO BATT
READ
& Temperature
Head
English
Average
(16 sec)
Metric
Real
time
English
Metric
Ft/min
M/s
MPH
KM/hr
ºF
ºC
OFF
AUTO-
OFF
AAV3
08
MFD
F
SYNC
%
Hz
Controls
°C
°F
O
F
F
SYNC
SC56
TRUE RMS
SC56
HOLD
O
Hz
TRUE RMS
F
A
AC
F
V
V
AC
DC
NCV
TRUE RMS
30V
MAX
HOLD
INRUSH
O
TRUE RMS
TRUE RMS
Hz
30V
TEMP
F
A
AC
MFD
F
V
V
MAX
Rotate dial to the function you want to use.
AC
DC
%
Hz
NCV
TEMP
30V
°C
°F
MAX
CAT III
INRUSH
HOLD
600V
TEMP
Cycle through parameters or ranges
TRUE RMS
CAT III
600V
SEL
within a dial position
CAT III
HOLD
30V
600V
MAX
MAX
TRUE RMS
MIN
TEMP
SEL
Press to illuminate backlight for 3 min
30V
MAX
CAT III
SYNC
TEMP
600V
Press to freeze maximum or minimum
MAX
CAT III
reading
MIN
600V
AUTO OFF
K-TYPE
Press to freeze the reading
TEMP
HOLD
TRUE RMS
AUTO OFF
CAT III
600V
30V
K-TYPE
MAX
TEMP
INRUSH
04
CAT III
600V
SC56
MicroAmps DC (µADC)
Microamps for flame rectifier diode test on a heater control.
Connect leads between flame sensor probe and control module and
turn heating unit on to read µA measurement. When the flame is on,
HOLD
O
there should be a measurable µADC signal, typically under 10µADC.
Hz
F
A
Compare measurement to manufacture's specification to determine if
AC
F
V
V
MFD
AC
DC
replacement is necessary.
%
NCV
Hz
Ranges: 1000µA Resolution: 0.1µA
°C
°F
Accuracy: ±(1.0% + 5 dgts) Voltage burden: 1V
INRUSH
Overload Protection: 600VDC or 600VAC rms
Frequency (Hz) Through Leads
Check variable frequency drives. Check incoming voltages to
ensure they are cycling at 60Hz or desired frequency. Select VAC/Hz
and press SEL button.
Ranges: 20 to 400Hz Resolution: 0.1Hz
SEL
Accuracy: ±(0.5% + 5)
Sensitivity: 5V rms on VAC range.
Capacitance (MFD)
Capacitors are one of the most failure prone components in
a HVAC/R system. Set to MFD/Ω/
to test motor start and run
capacitors. Discharge the capacitor and disconnect from power and
resistors between terminals before testing.
Ranges: 0 to 1000µF Resolution: 0.1µF
Accuracy: ±5% + 15 dgts
Overload Protection: 600VDC or 600VAC rms
TRUE RMS
AUTO OFF
30V
K-TYPE
MAX
09
TEMP
A
AC
HOLD
SEL
V
V
AC
DC
SEL
MAX
NCV
SEL
Display
MIN
SEL
INRUSH
SEL
Battery Life Indicator
SEL
SEL
Auto Power Off Enabled
TRUE RMS
AUTO OFF
SYNC
High Voltage Warning (+30V)
30V
K-TYPE
MAX
SEL
Manual Ranging
TEMP
Data Hold Mode
CAT III
MAX
600V
Maximum Reading
SEL
MIN
Minimum Reading
TRUE RMS
AUTO OFF
Continuity Test
AUTO OFF
TRUE RMS
AUTO OFF
Frequency Test (hertz)
MAX
SEL
TRUE RMS
30V
AUTO OFF
30V
K-TYPE
MAX
30V
MIN
Resistance Test (ohms)
K-TYPE
AUTO OFF
MAX
K-TYPE
MAX
TRUE RMS
TEMP
AUTO OFF
TEMP
TEMP
Capacitance Test (farads)
30V
AUTO OFF
K-TYPE
MAX
K-TYPE
Micro Unit (10
CAT III
, one millionth)
30V
−6
AUTO OFF
AUTO OFF
TEMP
600V
CAT III
K-TYPE
MAX
CAT III
K-TYPE
600V
Milli Unit (10
−3
, one thousandth)
600V
TEMP
30V
K-TYPE
K-TYPE
MAX
CAT III
TEMP
AUTO OFF
600V
CAT III
600V
CAT III
600V
K-TYPE
AUTO OFF
K-TYPE
TRUE RMS
AUTO OFF
05
30V
MAX
K-TYPE
TEMP
O
F
F
CAT III
600V
O
F
F
O
F
F
Discharge Cap First!
10
Need help?
Do you have a question about the SC54 and is the answer not in the manual?
Questions and answers