Intercom PREMIUM 400 - INOX Use And Maintenance Manual page 7

External suction vacuum packaging machines premium
Table of Contents

Advertisement

MANUAL CYCLE: pressing Start/Stop button, a time endless working cycle is on ( A letter for aspiration is shown on
the display).Once wished vacuum level is obtained in the bag, the operator will press SET/SEAL button to let the
sealing phase start, with automatic switch off of the pump.
AUTOMATIC CYCLE: when machine is in stand-by, dash/line in the centre of the display will be positioned on
MAN: pressing START/STOP, the operator will place the dash/line on AUT1 or AUT2.Automatically, the electronic
board will show time sealing (DEFAULT 3,5 sec),which can be modified..
Pressing START/STOP suction phase begins, and after 15 secs (AUT1) or 25 secs (AUT2) machine will automatically
pass to sealing and then download thus end working cycle phases.
APPROXIMATE VACUUMING TIME IN PLASTIC CONTAINERS
SMALL CONTAINER
MEDIUM CONTAINER
BIG CONTAINER
30 sec. approximately
40 sec. approximately
50 sec. approximately