Thank you for your purchase of the Tion О2 Breezer compact ventilation unit. 1. GENERAL The Compact Ventilation Unit Tion O2 Breezer (the «device» in what follows) is de- signed for active supply of considerable volumes of outside air into the building. This involves the following: •...
4, Table of Technical Parameters). Tion O2 Lite, Tion O2 Base and Tion О2 MAC Base versions are recommended for use in environmentally clean regions. To ensure enhanced air cleaning, Tion O2 Lite, Tion O2 Base, Tion О2 MAC Base devices should be outfitted with the appropriate additional...
Please contact any authorized service center of the Manufacturer to install the optional heater system (at additional cost). The user can upgrade the Tion O2 Base version to Tion O2 Standard without spe- cialist assistance, by installing additional filters. The Tion О2 MAC Base version can be similarly upgraded to Tion О2 MAC with additional filters.
Guarantee period, years Compatibility with MagicAir * Use of the Tion O2 Lite version at negative outside air temperatures may reduce its service life. ** Device performance depends on the operating conditions. 5. SCHEMATIC DIAGRAM AND OPERATING PRINCIPLE 5.1. Construction A schematic diagram of the device with maintenance panel removed (Tion O2 Standard version) is shown in Fig.1.
1. Air duct flap 8. Maintenance panel latches 2. Control buttons and LCD display 9. The device must not be used if the 3. Power switch power supply cord insulation or any 4. Base filter F7 (retainer of coarse part of the housing is damaged. dust F7) 10.
Page 11
The F7 base filter traps coarse and medium size dust particles, lint, soot and aller- gens with efficiency up to 90%. It extends the service life of the high-efficiency HEPA filter E11(H11). If necessary, the intake air can be heated to the required temperature. The high-efficiency HEPA filter E11 (H11) entraps the finest particles of dust, aller- gens, bacteria, viruses and mold spores with efficiency above 95%.
Page 12
Automated con- Inlet air tempera- Fan speed Temperature of Replace trol with MagicAir ture, °С air at the out- filters! system let, °С Days be- fore filter replace- ment The device is con- Timer-controlled device Heater off or Timer-controlled Timer nected MagicAir turn-on time: hours (if not installed...
Page 13
Figure 6. LCD display when the device is under manual control and filter replace- ment schedule is drawing near Error: Reference source not found Figure 7. LCD display when the device is under automated control of MagicAir sys- tem (section 5.4), heater is off or not installed in this configuration Figure 8.
Page 14
5.3.3 Remote control (RC) The remote control unit (Fig. 10) is used for manual remote control of the device: • switching the device between standby and active mode (section 5.3.5), • adjusting air flow (section 5.3.6), • adjusting target temperature (section 5.3.8), •...
Page 15
be switched off completely: press simultaneously and hold for 2 s the buttons [SET], [-] and [+] on the control panel (not available for RC operation). Sound signals are inactive when the device is in automatic mode (section 5.4). Type Value 1 signal «Command recognized», «Function enabled»...
Page 16
• pressing the button on the remote control; • timer-driven switching on/off, • automatic switching on/off with the MagicAir system (section 5.4). Device activation (switching from standby to active mode) is accompanied by a single beep, device deactivation by a double beep (in manual control mode, if sound signals are enabled).
Page 17
Filter Service Interval s: 360 days * A heater is not installed in Tion О2 Lite Lite configuration. ** If MagicAir is connected, the parameter cannot be adjusted. *** If the device is under control of MagicAir, the parameter cannot be adjusted.
Page 18
• If you are using the Tion О2 Lite version, the device should be turned off in the case of condensate or frost formation. It is recommended to resume operation only after its temperature warms up to the room temperature and traces of frosting disappear.
Page 19
In this case, turn on the heater and, if necessary, increase the target temperature to 10 °С. * A heater is not installed in Tion О2 Lite Lite configuration. 5.3.10 Current Time Time adjustment can be performed manually (using the control panel or remote control), if MagicAir (section 5.4) is not connected.
Page 20
Select the parameter «Timer on/off» with the [SET] button in the manual control mode. Press [+] or [-] buttons to switch between timer enabling/disabling. The timer mode is displayed as «ON» / «OFF» indication (Fig. 14). After selecting («ON») press [SET] to go to timer adjustment. The LCD display is then in the mode of configuring the timer-based device engagement (see Fig.15, where blinking segments are shown circled).
Page 21
5.3.12 Minimum Admissible Temperature This function is used for selecting the minimum ambient temperature, below which the device shuts down. The minimum admissible temperature is configured in manual mode (with control panel or remote control). The device will switch to standby mode if the outdoor temperature drops below this configured value and the warning message «ЕС02»...
Page 22
Blinking segments Figure 17. Configuration of filter replacement alert schedule PLEASE NOTE! Do not reset the counter without replacing filters. Operating the device with used filters can decrease performance, increase fan noise and cause device failure. 5.3.14 Saving settings in memory All parameters retain the configured values upon switching to and from the standby mode as follows: •...
Page 23
In accordance with programmed parameters, the MagicAir base station issues com- mands to the connected climate control units. By default the Tion О2 MAC and Tion О2 MAC Base Breezers are equipped with an interface module for connection with the MagicAir system. All other Breezer versions can be upgraded with this module at any authorized service center of the Manufacturer.
[SET] buttons on the device panel and hold for 2 s. The LCD will blink during the connection process. After a successful connect, a single beep will sound. The connec- tion process takes at most 30 s. In the case of a connection failure, a double warning beep is issued.
Page 25
Depending on the factory sealing procedure, the device filters (base F7, HEPA E11 (Н11) and adsorption catalytic АK filter) may be supplied in protective plastic packag- ing. Therefore, before first use, the filters must be unpacked (Fig. 18). Please do the following: 1.
6.2 Placement guidelines The device is most useful in rooms where people spend most of their time, i.e. those most affected by breathing: bedrooms, children’s rooms, living rooms, etc. Select the location of the unit taking into account its dimensions (height 514 × width 454 ×...
However, if the base filter F7 is cleaned and/or replaced on a correctly scheduled basis, the E11 (H11) HEPA filter may be replaced once every two years (depending on the operating conditions). The AK and AK-XXL adsorption catalytic filters must be replaced at least once a year, depending on the operating conditions.
If the «EC02» error message is displayed, make sure that the outer air temperature is above the value preset by the «minimum admissible temperature» parameter (sec- tion 5.3.11). If the outer air temperature conforms with the specified range, please contact the service center by phone, as indicated on the Warranty Card.
Tion О2 Breezer compact ventilation unit, congratulate you on your choice of this device and thank you for your purchase. The planned service life of the Tion Smart Microclimate JSC device is 5 years, sub- ject to the installation and operation guidelines.
Page 30
Manufacturer’s fault. Tion Smart Microclimate JSC reserves the right to deny of war- ranty terms, should the aforementioned conditions not be duly fulfilled. The warranty period is 1 year from the purchase date, on condition that the operating instructions are duly followed.
ACCEPTANCE CERTIFICATE Compact ventilation unit Tion О2 Breezer Corresponds to Technical Specifications TU 3646-001-66248641-2015 and is ac- ceptable for operation. Manufacturing date QC stamp...