OPERATION AND FUNCTIONS
1-2. Ice making mode
START
NO
130 min passed?
I-S<-12.5
Ice separating mode
1)
Ice making stops if ice-sensor is below -12.5 degree after 130 minutes.
2)
Ice making also stops if ice-sensor is below -9.5 degree for 15 minutes, though
ice-sensor is not below -12.5 degree after 130 minutes.
3)
In case of ice-sensor error, ice making stops after 4.8 hours.
2. Ice separating (drop) mode
status of
Ice tray
Ice separation start
Level SW
8-11
sec
Normal level SW
Motor revolution
.
Level SW error
1) Time of each zone is used to verify level switch error.
2) The rotation of motor is sensed at each zone.
3) In case of level switch error, ice separation is done by time.
4) If ice separating motor has error, the mode stop.
CONTENTS
YES
NO
C
YES
Max 1.1
8.5-12.2
sec
clockwise
counterclockwise
11
sec
10
sec
NO
I-S<-9.5
C
YES
NO
15 min passed?
YES
Horizontal position
0.2
sec
sec
c.w
stop
1.1
sec
29
REMARKS