Positioner Mounting And Orientation; Camflex Ii, Varimax, Minitork Ii, Ball Ii, And Hpbv; Mounting Parts Reference - GE Masoneilan 4700P Maintenance Manual

Pneumatic and electropneumatic positioners
Table of Contents

Advertisement

Positioner Mounting and Orientation

Camflex II, Varimax, MiniTork II, Ball II, and HPBV

The positioner is mounted to an intermediate plate (171) by two screws (29) and lockwashers (30)
with the gauges nearest the actuator on Camflex and Varimax (Figure 8) and with gauges away
from actuator on Ball II (Figure 9), MiniTork II (Figure 9), and HPBV (Figure 10). The intermediate
mounting plate (171) is held by two flat-head screws (172) to the bracket.
NOTE
Ref.
No.
29
Socket Head Screw
171
NOTE
28 | =GE Oil & Gas
The cam take-off hole must be centered about the shaft.
Table 3: Mounting Parts Reference
Description
Mounting Plate
The remainder of the mounting kit parts are used to before
tightening mounting screws. assemble the cam to the actuator.
See "Mounting Cam Coupling" on page 44.
Ref.
Description
No.
172
Mounting Plate Screws
30
Lockwashers
© 2015 General Electric Company. All rights reserved
.