  • Page 1 Please complete this information and retain this manual for the life of the equipment: Model #: __________________________ Serial #: __________________________ Date Purchased: ___________________ Installation and Operation Manual Covering Model Series SLG40 and SLG100 Gas Safety Certified AS 4563 Cert. GSCS20190 SAI Global L20-364 Rev 3...
  • Page 2 THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Do not spray aerosols in the vicinity of this appliance while it is in operation.
  • Page 3: Table Of Contents

    Table of Contents Checking your New Appliance ........................4         Assembly ................................4     Leg Installation and Leveling ..........................4     Heat Deflector Installation ............................5 Installation ..............................5         Installation Clearances ............................5  ...
  • Page 4: Checking Your New Appliance

    SLG I&O Series Checking your New Appliance Your new appliance has been carefully packed into one crate. Every effort has been made to ensure that you it is delivered to you in perfect condition. As you unpack your new appliance, inspect each of the pieces for damage.
  • Page 5: Heat Deflector Installation

    SLG I&O Series 1.3 Heat Deflector Installation If the appliance requires a heat deflector, you will find a removable label at the rear top edge of the unit. This label has instructions for positioning and installation of the heat deflector. Refer to the label and the instructions below to install the deflector.
  • Page 6: Gas Connection

    The gas inlet of the appliance is located in the back of the appliance on the lower RIGHT hand side for the SLG100 and lower LEFT hand side for SLG40 about 21 cm from the floor The gas line must be installed in accordance with the requirements of AS 5601 or local codes, by a qualified professional.
  • Page 7: Initial Adjustments

    SLG I&O Series Caution Ensure that your ventilation system does not cause a down draft at the appliance’s flue opening. A down draft will not allow the appliance to exhaust properly and will cause overheating, which may cause permanent damage. NEVER point a fan or similar device at or toward the flue opening of this appliance.
  • Page 8: Lighting Instructions

    SLG I&O Series Lighting Instructions For manual pilots, refer to the following instructions. Warning If pilot extinguishes, wait 5 minutes before attempting to relight the pilot to allow any built up gas to dissipate. Open gas supply valves to the appliance. Turn the thermostat control knob counterclockwise to the OFF position.
  • Page 9: Main Burner System Adjustment

    SLG I&O Series Replace the cap screw. 3.2 Main Burner System Adjustment For the main burners to operate the gas supply valve must be open and the thermostat must be turned on. For models with electric controls, the main power switch must be on. The main burners receive gas from the main gas supply through the thermostatically controlled valve.
  • Page 10: Filling The Tank

    SLG I&O Series DO NOT leave the appliance unattended during cleaning. Never let the water level go below the “Min Level” mark stamped on the tank. Using the cleaning brush, scrub the inside of the tank to remove the protective coating. When cleaning is complete turn the appliance off, drain the water into a container suitable for hot water and dispose of it.
  • Page 11: Filling The Tank With Solid Shortening/Oil

    SLG I&O Series 4.2 Filling the tank with solid shortening/oil To fill the tank with solid shortening/oil refer to the following procedure. Warning NEVER melt blocks of solid shortening/oil on top of the burner tubes. This will cause a fire and could result in personal injury.
  • Page 12: Appliance Shutdown

    SLG I&O Series 5.2 Appliance Shutdown There are two shutdown modes of appliance operation: STANDBY and COMPLETE. The standby mode removes the ability of the appliances main burners to operate. Complete shutdown turns off the gas supply to the appliance. STANDBY Turn the thermostat to the OFF position.
  • Page 13: Thermostat Calibration

    SLG I&O Series Light the pilot as described in this manual, set the thermostat to 325°F (163 °C) and allow the shortening/oil to come up to temperature. Watch the thermometer closely as the temperature rises. If the shortening/oil temperature reaches 350°F (167 °C) and the burners do not turn off, turn the thermostat down.
  • Page 14: Weekly Cleaning

    SLG I&O Series Weekly Cleaning The appliance should be thoroughly cleaned AT LEAST once a week. This should include a thorough wipe down of the entire appliance with a rag and mild detergent. Warning The power supply must be disconnected before cleaning and servicing this appliance! Warning NEVER spray cleaner into the main burners or pilot.
  • Page 15: Ventilation Hood Maintenance

    SLG I&O Series 10 Ventilation Hood Maintenance Proper ventilation hood operation is very important for the correct operation of this appliance and the safety of personnel. The ventilation hood should be inspected at the time of installation of this appliance to insure that it will operate properly in conjunction with the appliance.
  • Page 16: Basic Troubleshooting Flow Chart

    SLG I&O Series 12 Basic Troubleshooting Flow Chart Refer to this section to correct common problems that may be encountered during the course of normal operation. If applicable, a schematic is provided behind the panel containing the electrical components. Appliance does not work.
  • Page 17: Slg Series Operational Information

    SLG I&O Series 13 SLG Series Operational Information Model SLG40 SLG100 Total Gas Consumption 90 MJ/h 158 MJ/h Burner Pressure Natural Gas 0.87 kPa 0.87 kPa Burner Pressure Propane Gas 2.50 kPa 2.50 kPa Injector Size: Main Burners 2 of...
  • Page 18: Conversion Procedure

    Undo and remove the wingnuts from the top of the burners. Remove the wingnuts and burner retainer plate. Remove burner. This will make removing the pilot (on SLG40) or runner tube (on SLG100) easier. Loosen the brass fitting on the gas valve holding the pilot line.
  • Page 19 SLG I&O Series...
  • Page 20 SLG I&O Series In the event of problems with or questions about your In the event of problems with or questions about your order, please contact the Anetsberger Factory at: equipment, please contact the Anetsberger Authorized Service and Parts representative (ASAP) covering +001 (603) 225-6684 (World Wide) your area, or contact Anetsberger at the number listed to the left.