Anets SLG Series Service & Parts Manual

Anets SLG Series Service & Parts Manual

Hide thumbs Also See for SLG Series:

Advertisement

IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual
for the life of the equipment:
Model #: __________________________
Serial #: __________________________
Date Purchased: ___________________
Service & Parts Manual
Covering
SLG Series
L22-348 Rev 1, 5/13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLG Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Anets SLG Series

  • Page 1 IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment: Model #: __________________________ Serial #: __________________________ Date Purchased: ___________________ Service & Parts Manual Covering SLG Series  L22-348 Rev 1, 5/13...
  • Page 2 FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Do not spray aerosols in the vicinity of this appliance while it is in operation. WARNING Improper installation, alteration, service or maintenance can cause property damage, injury or death.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Leg Installation and Leveling ........................... 2 Installation Clearances ..........................2 Gas Connection ............................2 Gas Connection and Sealing Compound ....................3 Fuel Supply Line Leak and Pressure Testing ..................3 INITIAL ADJUSTMENTS ..........................3 Pilot Flame Adjustment after gas valve replacement ................3 Main Burner System Adjustment ......................
  • Page 4: Leg Installation And Leveling

    1 Leg Installation and Leveling This appliance must be installed with legs; it cannot be curb mounted. Curb mounting will seriously inhibit this appliances ability to effect proper combustion. WARNING This appliance must be installed with the legs provided by the manufacturer.
  • Page 5: Gas Connection And Sealing Compound

    1.3 Gas Connection and Sealing Compound As with any gas appliance, be sure to use a suitable gas joint sealant whenever gas connections are loosened and retightened. Also remember to check for leaks before allowing the appliance to be put into service. 1.4 Fuel Supply Line Leak and Pressure Testing The fuel supply system must be tested before the appliance is used.
  • Page 6: Main Burner System Adjustment

    2.2 Main Burner System Adjustment For the main burners to operate the gas supply valve must be open and the thermostat must be turned on. For models with electric controls, the main power switch must be on. The main burners receive gas from the main gas supply through the thermostatically controlled valve.
  • Page 7: For Gas Operated And Electric Thermostats Refer To The Following Procedure

    CAUTION If the burners do not shut off at the LOWEST thermostat setting, the thermostat may be defective. Contact your local service company. 3.2 For Gas Operated and Electric Thermostats refer to the following procedure. Remove the tube screen from the tank and place the tip of a digital thermometer in the shortening/oil approximately one inch above the temperature sensor.
  • Page 8: Trouble Shooting

    4 Trouble Shooting Refer to this section to correct common problems that may be encountered during the course of normal operation. If applicable, a schematic is provided behind the panel containing the electrical components. Appliance does not work. Is the gas Will the Open the gas supply...
  • Page 9: Testing The Thermocouple

    4.1 Testing the Thermocouple: You will need a multimeter that can measure millivolts. Make sure that after holding a flame to the thermocouple it produces 30 mv. You can test for this by heating the thermocouple for about a minute and then place one lead on the copper casing of the thermocouple and the other lead on one of terminals of the hi limit wire connection.
  • Page 10: Slg40 Exploded Parts Diagram

    5 SLG40 Exploded Parts Diagram L22-348 R1 5/13...
  • Page 11: Slg40 Exploded Parts List

    LEG, SET 6" WITH HARDWARE (SET OF 4) P0093300 NUT, HEX (KEP) 1/4-20 ZINC PLATED 60084501 DRAIN VALVE, 1 1/4 NON-LOCKING P9204-75 ANETS NAME PLATE BLACK/YELLOW PP10668 NUT, 1/4-20 ACORN WITH CENTERLOCK STAINLESS P0080650 WASHER, FLAT 1/4 ZINC A2510101 TANK, NIPPLE DRAIN OUT 1 1/4 NPT A4500601 WIRING RACK, TUBE 13.50 X 13.50...
  • Page 12: Slg100 Exploded Parts Diagram

    6 SLG100 Exploded Parts Diagram L22-348 R1 5/13...
  • Page 13: Slg100 Exploded Parts List

    LEG, SET 6" WITH HARDWARE (SET OF 4) P0093300 NUT, HEX (KEP) 1/4-20 ZINC PLATED 60084501 DRAIN VALVE, 1 1/4 NON-LOCKING P9204-75 ANETS NAME PLATE BLACK/YELLOW PP10668 NUT, 1/4-20 ACORN WITH CENTERLOCK STAINLESS P0080650 WASHER, FLAT 1/4 ZINC A2510101 TANK, NIPPLE DRAIN OUT 1 1/4 NPT...
  • Page 14: Slg40 Gas Assembly Exploded Au & Ce Diagram

    7 SLG40 Gas Assembly Exploded AU & CE Diagram L22-348 R1 5/13...
  • Page 15: Slg40 Gas Assembly Exploded Au & Ce Parts

    7.1 SLG40 Gas Assembly Exploded AU & CE Parts ITEM# PART# PART DESCRIPTION A8049901 PIPING, MANIFOLD BRACKET FRONT SLG40 PP11001 GAS VALVE G20 U7000 SLG40 PP11002 GAS VALVE G31 U7000 SLG40 PP11110 GAS VALVE G20 BGOL/S UNREGULATED 60179801 INTERRUPTOR,MV 11/32 THREAD P7037090 NIPPLE, BLACK 1/2 NPT X CLOSE P7037750...
  • Page 16: Slg100 Gas Supply Exploded Au & Ce Diagram

    8 SLG100 Gas Supply Exploded AU & CE Diagram L22-348 R1 5/13...
  • Page 17: Slg100 Gas Supply Exploded Au & Ce Parts

    8.1 SLG100 Gas Supply Exploded AU & CE Parts PLOT PART# PART DESCRIPTION P9315-61 PIPING, WELDMENT GAS MANIFOLD SLG100 PP10955 GAS VALVE G20/G25 U7000 PP10956 GAS VALVE G31 U7000 PP11110 GAS VALVE G20 BGOL/S UNREGULATED PP10067 GAS SUPPLY METRIC ADAPTER NIPPLE, BLACK 1/2 NPT X 2"...
  • Page 18: Tstat Assembly Exploded Au Diagram

    9 TSTAT Assembly Exploded AU Diagram L22-348 R1 5/13...
  • Page 19: Tstat Assembly Exploded Au Parts

    9.1 TSTAT Assembly Exploded AU Parts ITEM# PART# PART DESCRIPTION PP10084 SWITCH, HI-LIMIT P5047590 THERMOSTAT, GS 190C B14503-00 PIPING, BRACKET THERMOSTAT WITH IGNITOR PP10687 SCREW, 6-32 X 5/16 TH PHILLIPS PP10539 KNOB, THERMOSTAT P0007300 SCREW, 8-32 X 1/4 HEX HEAD ZINC B6744402 WIRING, MILLIVOLT HI-LIMIT/THERMOSTAT P9132-34...
  • Page 20 In the event of problems with or questions about In the event of problems with or questions about your order, please contact the Anetsberger your equipment, please contact the Anetsberger Factory at: Authorized Service and Parts representative (ASAP) covering your area, or contact +001 (603) 225-6684 (World Wide) Anetsberger at the number listed to the left.

Table of Contents

Save PDF