Download Print this page

Panasonic SL-CH22 Instruction Manual

Sensor & wire-saving link system s-link 2 channel output unit

Advertisement

Quick Links

INSTRUCTION
MANUAL
Sensor & Wire-saving Link System S-LINK
2 Channel Output Unit
SL-CH22, SL-CH22-PN
MJEC-SLCH22 No.0055-62V
Thank you very much for using Panasonic products.
Please read this Instruction Manual carefully and
thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient place
for quick reference.
Never use this product with a device for
personnel protection.
In case of using devices for personnel
protection, use products which meet laws
and standards, such as OSHA, ANSI or
IEC etc., for personnel protection appli-
cable in each region or country.
WARNING
Before touching this product, remove any
electrostatic charge that may be present
on your body. There is a danger of this
product getting damaged due to the elec-
trostatic charge.
1
OUTLINE
● This links two output devices to the S-LINK system.
<Application>
The S-LINK system control the double solenoid valves
through the SL-CH22 or the SL-CH22-PN.
Users' output device
(Electromagnetic valve etc.)
2 channel output unit
SL-CH22 or SL-CH22-PN
2
PART DESCRIPTION
G (Black)
D (White)
S-LINK side (LINK SIDE)
0V (Blue)
flat cable of 0.6m long with
0.5mm
2
conductor tin-plated
+24V (Brown)
Transmission indicator
Address set-up switch
(Green)
ADDRESS
ON
Use a long-tapered tool
Brinks in corresponding
of which tip is less than
to the synchronizing sig-
1
0.8mm wide to toggle
2
nal sent from the S-LINK
4
8
the switches, tweezers
16
control unit
32
NOT
or the like.
OFF
64
USED
Make sure to operate the
Operation indicator
SL-CH22
switch while the power is
(2-color indicator)
off and after taking coun-
SEND
Output 1 indication: Orange
termeasures, such as,
(Lights up when the output 1 is ON)
OUT1:OG
wrist strap, etc., against
Output 2 indication: Green
electrostatic change.
OUT2:GN
(Lights up when the output 2 is ON)
I/O
SIDE
OUT 2 (Pink / Gray)
Users' device side (I/O
OUT 1 (Pink)
SIDE) flat cable of 0.4m
0V (Blue)
long with 0.5mm
+24V (Brown)
tor tin-plated
3

SPECIFICATIONS

Type
NPN type
Item
Model No.
SL-CH22
24V DC±10% (supplied from the S-LINK control
Supply voltage
unit or other power supplies)
6mA or less
Current consumption
(except for connected devices)
Allowable through
Total 0.4A or less (including the current consump-
current
tion of this unit and the connected devices)
FAN-in
NPN open-collector transistor
(Photo-coupler isolation)
・Maximum sink current: 100mA
・Applied voltage: 30V DC or less
Output
(between output and 0V)
・Residual voltage:
(Output 1, Output 2)
1.5V or less
(at 100mA sink current)
0.4V or less
(at 16mA sink current)
The output transistor turns on when the S-LINK sends the
Output operation
output signal assigned ON through the transmission line.
Output point
Two output
Transmission
Green LED (blinks to indicate the synchronizing
indicator
signal sent from the S-LINK control unit)
Output 1 indication: Orange LED
(lights up when the output 1 is ON)
Operation indicator
Output 2 indication: Green LED
(lights up when the output 2 is ON)
Ambient temperature
0 to +55℃ (No dew condensation), Storage: -20 to +70℃
Ambient humidity
35 to 85% RH, Storage: 35 to 85% RH
Material
Polycarbonate
S-LINK side: 0.5mm
Cable
Users' device side: 0.5mm
Weight
55g approx.
4
OUTPUT CIRCUIT DIAGRAMS
The output does not incorporate a short-circuit protection
circuit. Do not connect it directly to a power supply or a
capacitive load.
● NPN type / SL-CH22
Color code
+24V DC (Brown)
T
r1
D (White)
Z
T
r2
G (Black)
Z
0V (Blue)
Internal circuit
S-LINK side
(LINE SIDE)
● PNP type / SL-CH22-PN
Color code
+24V DC (Brown)
D (White)
T
r3
Z
G (Black)
T
r4
0V (Blue)
Internal circuit
S-LINK side
(LINE SIDE)
Symbols... Z
, Z
, Z
, Z
: Surge absorption zener diode
D1
D2
D3
D4
T
, T
: NPN output transistor
r1
r2
2
conduc-
T
, T
: PNP output transistor
r3
r4
5
CONNECTING CABLE
PNP type
Make sure that the power supply is off while wiring.
SL-CH22-PN
Connecting S-LINK line
Use the SL connector to
12mA or less
hook up S-LINK side cable
(except for connected devices)
of the SL-CH22 or the
SL-CH22-PN to the S-LINK
field cable.
2.4
Colors should be matched
PNP open-collector transistor
between both cable.
(Photo-coupler isolation)
・Maximum source current: 100mA
・Applied voltage: 30V DC or less
(between output and +V)
Connecting Users' output devices
・Residual voltage:
1.5V or less
Using the socket-branch hook-up connector SL-JK
(at 100mA source current)
(for cable end) or SL-JK1 (for T-branching) and the
0.4V or less
snap male connector SL-CP1 (for 0.08 to 0.2mm
(at 16mA source current)
ble) or SL-CP2 (for 0.3mm
the connection work for output devices. However, take
care that there are output devices which can not be
connected.
Refer to the instruction manual enclosed with each
connector for details.
2
4-core flat cable 0.6m long
2
4-core flat cable 0.4m long
SL-JK1 (Blue)
(For T-branching)
SL-JK (Light blue)
(For terminating)
6
ADDRESS SETTING
Make sure to operate the switch while the power is off
Color code
and after taking countermeasures, such as, wrist
(Brown) +24V DC
strap, etc., against electrostatic charge.
The address of output 1 is 127 or less. If the address
Load
(Pink) Output 1
of output 2 is over 127, the S-LINK system does not
Load
work properly.
100mA max.
D1
(Pink / Gray) Output 2
The address of output 1 is given by the sum of all val-
100mA max.
ues that corresponding bits are set ON, and the ad-
D2
(Blue) 0V
dress of output 2 is made up by adding one to output 1
address.
Uses' device side
The address range is;
(I/O SIDE)
Output 1: 0 to 126, Output 2: 1 to 127
The right-most bit is not assigned (NOT USED).
Color code
No matter which it is ON or OFF.
(Brown) +24V DC
(e.g.)
Z
ON
D3
100mA max.
(Pink) Output 1
D4
100mA max.
Load
(Pink / Gray)
1
Load
Output 2
2
4
(Blue) 0V
8
16
Uses' device side
32
NOT
(I/O SIDE)
OFF
64
USED
Address set-up switch
7
The MS-SLH (optional) can fix the SL-CH22 and
the SL-CH22-PN.
SL connector
<Mounting>
S-LINK
field
Mount the MS-SLH with M4 pan head screws.
The tightening torque should be 0.8N・m or less.
Color matching
Press the SL-CH22 or the SL-CH22-PN onto the
MS-SLH.
Note:
<Dismounting>
Insert a flathead driver into the gap between them
as below.
2
ca-
Tilt the flathead screwdriver outward.
2
cable) enables to save
Users' output device
(Beacon etc.)
SL-CP1 or
8
SL-CP2
Users' output
● This product has been developed / produced for in-
device
dustrial use only.
(Relay etc.)
9
SL-CP1 or
SL-CP2
● The models listed under '
CATIONS' come with CE Marking.
As for all other models, please contact our
office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
Please refer to the 'S-LINK Design Manual' for details
of the entire S-LINK system.
Output 1 address = 2 + 4 + 32 = 38
Output 2 address = (Output 1 address) + 1
= 38 + 1 = 39
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
2 CHANNEL OUTPUT UNIT
HOLDER MS-SLH (OPTION)
M4 pan head screws are not enclosed with MS-SLH. Please
arrange them separately.
CAUTIONS
INTENDED PRODUCTS FOR
CE MARKING
3
SPECIFI-
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
PRINTED IN JAPAN

Advertisement

loading

This manual is also suitable for:

Sl-ch22-pn