ABB REM615 List Manual page 25

Relion 615 series, motor protection and control rem615 ansi dnp3 point list manual
Hide thumbs Also See for REM615:
Table of Contents

Advertisement

1MAC254287-MB B
DNP
No
Point
Object
DNP Class
Event
Index
Type
BI
20
Class 1 and 0
BI
21
Class 1 and 0
BI
22
Class 1 and 0
BI
23
Class 1 and 0
BI
24
Class 1 and 0
BI
Yes
25
Class 0
BI
Yes
26
Class 0
BI
Yes
27
Class 0
BI
Yes
28
Class 0
BI
Yes
29
Class 0
BI
Yes
30
Class 0
BI
Yes
31
Class 0
BI
32
Class 1 and 0
BI
33
Class 1 and 0
BI
34
Class 1 and 0
AI
Yes
5
Class 0
AI
Yes
6
Class 0
AI
Yes
7
Class 0
AI
Yes
8
Class 0
AI
Yes
9
Class 0
AI
Yes
10
Class 0
AI
Yes
11
Class 0
AI
Yes
12
Class 0
AI
Yes
13
Class 0
AI
Yes
14
Class 0
REM615 ANSI
Point List Manual
Enabled Description
Yes
52CM Number Of Recloser Operations
Exceeds Alarm Limit 1
Yes
52CM Number Of Recloser Operations
Exceeds Lockout Limit 1
Yes
52CM Recloser Not Operated For Long
Time Alarm 1
Yes
52CM Pressure Below Alarm Level 1
Yes
52CM Pressure Below Lockout Level 1
Yes
52CM Recloser Position Is Open 1
Yes
52CM Invalid Position 1
Yes
52CM Recloser Position Is Closed 1
Yes
52CM Reset Accumulation Energy 1
Yes
52CM Reset Input For Recloser
Remaining Life And Operation Counter 1
Yes
52CM Reset Travel T 1
Yes
52CM Reset Spr.Charge T 1
Yes
52CM Accumulated Currents Power (Iyt)
Exceeded Alarm Limit 1
Yes
52CM Accumulated Currents Power (Iyt)
Exceeded Lockout Limit 1
Yes
52CM Remaining Life Of Recloser
Exceeded Alarm Limit 1
Yes
52CM The Number Of Days Recloser
Has Been Inactive 1
Yes
52CM Travel Time Of The Recloser
During Opening Operation 1
Yes
52CM Travel Time Of The Recloser
During Closing Operation 1
Yes
52CM The Charging Time Of The
Recloser Spring 1
Yes
52CM Phase A Recloser Monitoring
Remaining Life 1
Yes
52CM Phase B Recloser Monitoring
Remaining Life 1
Yes
52CM Phase C Recloser Monitoring
Remaining Life 1
Yes
52CM Phase A Accumulated Currents
Power (Iyt) 1
Yes
52CM Phase B Accumulated Currents
Power (Iyt) 1
Yes
52CM Phase C Accumulated Currents
Power (Iyt) 1
Section 2
DNP3 data mappings
Scale
IEC61850 Data Attribute Name
Factor
LD0.SSCBR1.OpNumAlm.stVal
LD0.SSCBR1.OpNumLO.stVal
LD0.SSCBR1.LonTmAlm.stVal
LD0.SSCBR1.PresAlm.stVal
LD0.SSCBR1.PresLO.stVal
LD0.SSCBR1.PosOpn.stVal
LD0.SSCBR1.PosIvd.stVal
LD0.SSCBR1.PosCls.stVal
LD0.SSCBR1.RsAccAPwr.stVal
LD0.SSCBR1.RsCBWear.stVal
LD0.SSCBR1.RsTrvTm.stVal
LD0.SSCBR1.RsSprChaTm.stVal
LD0.SSCBR1.APwrAlm.stVal
LD0.SSCBR1.APwrLO.stVal
LD0.SSCBR1.CBLifAlm.stVal
0
LD0.SSCBR1.InaTmdCnt.stVal
100
LD0.SSCBR1.TmmsOpn.mag.f
100
LD0.SSCBR1.TmmsCls.mag.f
100
LD0.SSCBR1.TmsSprCha.mag.f
0
LD0.SSCBR1.RmnLifPhA.stVal
0
LD0.SSCBR1.RmnLifPhB.stVal
0
LD0.SSCBR1.RmnLifPhC.stVal
100
LD0.SSCBR1.AccAPwrPhA.mag.f
100
LD0.SSCBR1.AccAPwrPhB.mag.f
100
LD0.SSCBR1.AccAPwrPhC.mag.f
19