User's Manual
7.0 Adjustment Possibilities
After alignment of the controller associated with the oscillating conveyor, the necessary adjust-
ments by the user are limited to the setup of the conveyor capacity.
Parameter:
Oscillating conveyor
• Oscillation amplitude (conveyor capacity)
To adapt the oscillating conveyor, the following adjustments are possible
Parameter:
Oscillating conveyor
• Oscillating amplitude (conveyor capacity)
Service
• Oscillation frequency
• Soft start ramp time
• Soft stop ramp time
• Enable function invert
• Display software version number
Accsess Code: 406
8.0 Operating Panel
8.1 Adjustment Procedure
I
F
0
P
When depressing the arrow keys, a quick depression of the key will increase or decrease the display by
one place (one or ten), respectively. If the key remains depressed, after the next full decade the display
changes by decades.
In order to prevent accidental or unauthorized adjustment, the adjustment parameters in operating menus
are secured via operator codes. To access the operating menus, an operator code must be entered. Dif-
ferent operator codes (functional depth) are available.
Modified adjustment values are only permanently stored either when the programming mode is
exited or after 60 seconds have elapsed with no key depression.
SOR 3
0...100 %
0...100 %
30...140 Hz
0...10 sec.
0...10 sec.
0 / 1
Value increase
Value decrease
back
F
Programming mode
P
or accept
Code
Basic
Factory
Adjustment:
A.
50 %
Code
Basic
Factory
Adjustment:
A.
50 %
F.
100 Hz
/.
0.1 sec.
\.
0.1 sec.
-En.
0
I
Start
0
Stop
Access
code:
000, 406
Access
code:
000, 406
406
406
406
406
001
5