Specifications
2-2 Electrical
Input Voltage
DC Output Voltage
Line Regulation
Load Regulation
Ripple Noise
Over Current Protect
Power Consumption
Warming Up Time
First Print Time
Acoustic Noise
Reliability
Insulation Resistance
Dielectric Strength
Ground Continuous
Voltage DIP
AC Impulse Noise
Leakage Current
Surge
Ozone Emission
Top Cover Open
Overcurrent Protect
Fusing System
Trouble Sensing
Overheat Sensing
Thermistor Open Sensing
Source of Light
Developer
Developing
Charging
Density Adjustment
Transfer System
Fusing System
Ozone Emission
2-2
EUROPE : AC 200~240 V ± 15 %, 50/60 Hz ± 3 Hz
USA : AC 110~120 V ± 15 %, 50/60 Hz ± 3 Hz
24 V ± 3 %
5 V ± 2 %
24 V - 3 %/+10 %
5 V ± 3 %
24 V : 120 mV (Peak 400 mV)
5 V : 50 mV (Peak 100 mV)
24 V : 2.7 A ± 10 % (by C't )
5 V : 1.5 A ± 10 % (by C't )
Max. 630 Wh
Everage: 350 Wh
Power Save Mode: 10W or less
25 seconds or less
Idle mode : 15 seconds or less(face up)
Power Save mode : 30 seconds or less
Standby : 36 dB or less
Sleep Mode: Background level
Operating : 48 dB or less
10 Mohm or less (at DC 500 V)
AC 1500 V (DC 2100 V), 10 mA
0.1 ohm or less
Rated voltage ± 15 %
AC 1000 V 10, 100, 200, 400, 1000 ns
3.5 mA or less
0.5 ~ 4 kV, 0.25 ~ 2 kA
0.1 ppm or less (8 hours)
Isolating the input power of the LSU, high voltage part, and fuser
Fuse inside the Engine Controller
The temperature doesn't rise to the specific temperature within a
specific time. Fuser error occurs if the temperature is too high.
240 ~ 250
C (The thermostat cuts off the Fuser from the power.)
o
Without the initial temperature change of the Fuser
Laser Diode (LSU)
Non-magnetic contact developing
Conductive roller charging
Dark, Medium
Pre-transfer by LED & conductive roller
Temperature & Pressure
0.1 PPM or less (8 hours)