Series 200 Insertion Style Flow Sensors IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. 872020-EN (August 2012) Installation & Operation Manual Rev. 8...
Any circumferential location is correct for installation in vertical pipes. Used in conjunction with any Badger Meter impeller flow monitor or transmitter, Badger Meter non-magnetic flow An insertion depth of 1-1/2 inches for pipe sizes sensors provide an accurate rate of liquid flow as well as 2.5 inches and larger is required for accurate flow...
225BR, 226BR, AND 226SS Clean O-rings and flow sensor sleeve, and lightly Badger Meter Series 200 hot tap style liquid flow sensors lubricate O-rings with silicone grease from the packet are designed for use in cases where pipelines will be in provided or some other acceptable lubricant.
225H consult technical bulletin DID-001. development of the flow profile. For pipe sizes 2½” and above; all Badger Meter sensors Install either a service saddle or welded pipe fitting (2 are inserted 1 1/2” from the inside wall of the pipe. The...
Route the cable from the sensor to a Badger Meter hex mounting adapter. At this point the sleeve will flow monitor/transmitter. The cable may be extended have been inserted past the top two “O”-rings in the...
ELECTRICAL INSTALLATION absolutely necessary. The Series 200 sensor is approved, as an entity, as Route the cable from the sensor to a Badger Meter intrinsically safe when installed in conformance with flow monitor/transmitter. The cable may be extended Badger Meter installation drawing 06-480-002 as specified up to 2000 feet, using 2-conductor shielded 20 AWG on the blue label identifying an intrinsically safe sensor.
Page 8
Series 200 Flow Sensors Page 8 August 2012...
CALIBRATION Column 6 This column indicates the suggested flow range of Badger Meter sensors use unique K and Offset numbers sensors in each pipe size. for calibration. These numbers are derived from calibration Badger Meter sensors runs using NIST traceable instruments. Using both a K and...
Refer to figure 4. To reinstall, position the impeller in the cavity oriented as in step 4 so that the impeller If you are replacing an existing Badger Meter sensor and blades point into the flow direction and toward have already calibrated your flow monitor/transmitter, the small alignment hole located beside one of the no calibration changes are necessary.
UNS C83600 analog transmitter unit. Rated to 1050C. May be extended to a maximum of 2000 feet with similar Sensor Sleeve and Hex Adapter for 220SS and 226SS cable and insulation appropriate for application. • Series 300 stainless steel...
Page 14
Series 200 Flow Sensors This page intentionally left blank. Page 14 August 2012...
Page 15
Installation & Operation Manual This page intentionally left blank. August 2012 Page 15...
Page 16
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0 Czech Republic | Badger Meter Czech Republic s.r.o.