Cleaning The Front Grille - Daikin FTXD60JV1B User Manual

Ftxd-j series, flx-j series, rxd-j series inverter pair
Hide thumbs Also See for FTXD60JV1B:
Table of Contents

Advertisement

SiBE04-101.book Page 61 Monday, October 15, 2001 3:08 PM
SiBE04-101
Care and Cleaning

Cleaning the front grille

You may remove the front grille for cleaning.
CAUTION
When removing or attaching the front grille, use a robust
and stable stool and watch your steps carefully.
When removing or attaching the front grille, support the
grille securely with hand to prevent it from falling.
For cleaning, do not use water hotter than 40˚C, benzine,
gasoline, thinner, nor other volatile oils, polishing
compound, scrubbing brushes nor othe hard stuff.
After cleaning, make sure that the front grille is securely
fixed.
1
Open the front grille.
Hold the grille by the tabs on the two sides
and lift it until it stops with a click.
2
Remove the front grille.
Supporting the front grille with one hand, release
the lock by sliding down the knob with the other
hand.
To remove the front grille, pull it toward yourself
with both hands.
3
Clean the front grille.
You may wipe it with a soft cloth soaked in water.
Only neutral detergent may be used.
You may wash the grille with water. After washing,
dry it with cloth, then dry it up in the shade.
4
Attach the front grille.
Set the 3 keys of the front grille into the slots and
push them in all the way.
Supporting the front grille with one hand, fit the
lock by sliding up the knob with the other hand.
Close the front grille slowly in this state. (Push
the grille at the 3 points, two at both sides and in
the middle.)
Fit the key
into the slot.
System Configuration
Check
Check that the base, stand and other
fittings of the outdoor unit are not
decayed or corroded.
Check that nothing blocks the air
inlets and the outlets of the indoor unit
and the outdoor unit.
Check that the earth wire is not
disconnected or broken.
Check that the drain comes smoothly
out of the drain hose during COOL or
DRY operation.
If no drain water is seen, water may be
leaking from the indoor unit. Stop
operation and consult the service shop if
this is the case.
Before a long idle period
1 Operate the fan alone for several
hours on a fine day to dry out the in-
side.
1
Press
2
Press
temperature to 32˚C
3
Press
• Perform this operation when the room
temperature is under 28˚C.
2 Clean the air filters and set them
again.
3 Take out batteries from the remote
controller.
4 Turn OFF the breaker for the room
air conditioner.
Side up the knob.
Instruction
MODE
MODE
and select "
".
and set the
ON/OFF
.
17
61

Hide quick links: