  • Page 1 .it AQ USER OPERATING INSTRUCTIONS...
  • Page 2: Dear Customer

    Dear Customer, In congratulating you for purchasing one of our heat stoves, we would like to remind you that pellet heat stoves are the most innovative heating solution, the result of the most advanced technology with an extremely high level of workmanship quality. Their neat and elegant design fits well into any room and makes it cosy thanks to the unique enveloping warmth that fire alone is able to give.
  • Page 3: Technical Specifications

    Technical Specifications Ø 80 Ø 50 Approximate dimensions (mm). Weight Kg 145 Flue gas exhaust pipe diameter 80 mm Air inlet pipe diameter 50 mm Water inlet/outlet diameter 3/4” Power supply 230V - 50Hz Min. electric consumption 90 W Min. electric consumption 350 W in ignition phase only Tank capacity 17 kg / 26 litres...
  • Page 4 Heat Stove Ignition SYMBOL DESCRIPTION ATTENTION! The burn pot must be cleaned before each The LED flashes when the panel ignition. receives a temperature/power change signal from the infrared remote control. Control panel (Fig. 2) The button is used to ignite or extinguish the The LED is on when the room heat stove and to quit programming.
  • Page 5 Heat Stove Ignition Ignition PLEASE NOTE: In the event there should be repeated failed Press button for a few seconds until the heat ignitions, but the pellets are fed properly, there might be an issue connected to breakage of the stove starts.
  • Page 6: Room Temperature Adjustment

    Heat Stove Ignition Room temperature adjustment ATTENTION! adjust room To extinguish the heat stove, do not unplug temperature press it but let the automatic extinction cycle end: button twice: the lower prolonged flue gas exhaust fan operation is display will show the words normal and may indicate that the stove is "SET AIR"...
  • Page 7 Chronothermostat The chronothermostat function is used to program Parameter Description Settable values automatic cycling on and off of the heat stove throughout the week. Adjustment fourth From 00:00 to 23:50 UT15 To enter programming hold the button with 10 minute steps heat stove extinction...
  • Page 8 Chronothermostat UT02 Display Display Set current hour MEANING bottom This parameter is used to set the current hour, ON1/OFF1-Yes or No Day 1 Monday press buttons to select the current time. ON2/OFF2-Yes or No Day 2 Tuesday Press button to move to the next parameter. Day 3 ON3/OFF3-Yes or No Wednesday...
  • Page 9: Remote Control

    Remote control The remote control (Fig. 3) is used to adjust water temperature, power and heat stove ignition/ extinction. Press key to ignite the heat stove, the heat stove automatically enters the start up stage. Press keys to adjust water temperature, while use keys adjust operation power.
  • Page 10: Alarm Signals

    Electrical device faults Alarm signals In the event a heat stove operation fault should The following table summarises the alarms, type occur, the system informs the user on the type of of problem and possible solution: fault. Display Display Solution Type of problem Bottom -The heat stove is unable to ignite...
  • Page 11: Failed Ignition

    Electrical device faults Failed ignition ATTENTION! If no flame develops during the ignition stage or do not try igniting the heat stove before the flue gas temperature does not reach an ade- the required time, as it might lock down. quate level in the time interval set for ignition, the In the event of lock turn off the switch at stove in set to extinction and the display reads...
  • Page 12: Water Temperature Safety

    Electrical device faults Flue gas exhaust safety System pressure safety A mechanical vacuum pump ensures there is The system pressure is controlled electronically the right vacuum for proper fl ue gas exhaust. and must be kept between 0.5 and 2.3 bar. If this Otherwise, in the event of fl ue obstruction, the is not so the heat stove goes into alarm mode and heat stove goes into extinction mode and the...
  • Page 13 Heat stove cleaning The heat stove needs simple and accurate After burning three-four bags of pellets, open the cleaning in order to always assure efficient lower door and unscrew the two knobs that hold performance and regular operation. the inspection pan (Fig. 8); During internal cleaning of the heat stove the flue gas fan may be started to prevent spilling Fig.
  • Page 14: Wiring Diagram

    Wiring diagram 230V Mains filter...
  • Page 15 NOTES...
  • Page 16 46033 casteldario - mantova - Italy - tel. +39 0376 57001 - telefax +39 0376 660556 info@unical-ag.com - export@unical-ag.com - www.unical.eu Unical shall not be held liable for any inaccuracies due to transcription or printing errors. Furthermore, it reserves the right to modify its products as deemed necessary or useful, without affecting their essential features.

Table of Contents