Download Print this page

Cable Connections; Resetting The Camera - Honeywell HDZ302LIW Quick Installation Manual

Hdz ir series ip ptz dome

Advertisement

Cable Connections

Before connecting the cables, take a minute to familiarize yourself with the cables, as shown
in the figures and table below.
Red
AC24V
Power
Black
AC24V
Yellow & Green
Earth
Yellow
A+
RS485
Orange
B-
Video Out
BNC
Network
RJ45
Red
Audio OUT
Audio
White
Audio IN
Black
Audio GND
Blue
Alarm OUT 1
Black
Alarm OUT 2
Alarm Out
Green
Alarm COM1
Pink
Alarm COM2
Yellow & Green
Alarm GND
Red
Alarm IN 1
Brown
Alarm IN 2
Gray
Alarm IN 3
Alarm In
Light Green
Alarm IN 4
Purple
Alarm IN 5
White
Alarm IN 6
Yellow & Black
Alarm IN 7
Note: The Ethernet cable should not be longer than 328 ft (100 m).
Important Note:
Regarding PoE Operation of models HDZ302LIW/HDZ302LIK
A high power PoE injector capable of supplying at least 60 W is required for proper
operation of outdoor camera models HDZ302LIW / HDZ302LIK (NOTE – Using PoE to
IEEE802.3af or IEEE802.3at will not support these models).

Resetting the Camera

Press and hold the Reset button for 10 seconds when the camera is powered on to reset
the camera (refer to below image for Reset button location).
Power
RS485
Vide o Out
N e twor k
Audio
A la r m Out
Camera Cables
A la r m In
Outputs (x2):
Relay output, 120 V AC/30 V
DC, 3 A MAX
Use alarm outputs for SELV
circuits only.
Inputs (x7):
3.3V, 10k Ohms,
pull up
Reset Button
Before Logging In to the Camera
Before logging in to the camera, ensure that Internet Explorer is set up to run ActiveX
controls. You can enable ActiveX controls manually or by setting the browser's security
settings to the default level.
ActiveX Controls and Plug-ins
Settings
1.
Open Internet Explorer.
2.
On the Tools menu, click Internet
Options, and then click Security.
3.
Click the Internet icon, and then
click Custom Level.
4.
Set all ActiveX controls and plug-
ins to Prompt or Enable, and then
click OK.
Logging In to the Camera
Honeywell
Honeywell Confidential
&Pr opr ietar y
Honeywell Inter national Inc.
Copyr ight 2016
All r ight r eser ved.
HDZ IR Software & Document
1
2
3
1
x x
4
Note: By default, the camera has a dynamically assigned IP address (DHCP) and it
will default to 192.168.1.188 if there is not DHCP server. After finding the camera with
the IPC Tool, you can log in and assign a static IP address to the camera, or
otherwise modify the network and some other settings.
3
Internet Security Level
1.
Open Internet Explorer.
2.
On the Tools menu, click Internet
Options, and then click Security.
3.
Click the Internet icon, click
Default Level and click OK.
4.
Close the browser window and
open a new one to access the
camera.