Download Print this page
CyberPower DL450ELCD User Manual
CyberPower DL450ELCD User Manual

CyberPower DL450ELCD User Manual

Advertisement

Quick Links

DL450ELCD / DL650ELCD / DL850ELCD
User's Manual

IMPORTANT SAFETY INSTRUCTIONS

This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read
and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install,
or operate.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an
outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the UPS.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or
medical applications. DO NOT use in any circumstance that would affect the operation or safety of any life support equipment, with any medical
applications, or patient care.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is disconnected.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive
contaminants. (Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before installing a computer component.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near aquariums. Condensation from the
aquarium can come in contact with metal electrical contacts and cause the machine to short out.
CAUTION! DO NOT USE WITH LASER PRINTERS! The power demands of laser printers are too large for a UPS.

INSTALLING YOUR UPS SYSTEM

UNPACKING
The box should contain the following:
(1) UPS Unit x 1; (2) User Manual x 1;(3)
USB cable x 1;(4) Management software Disk x 1
OVERVIEW
The DL450ELCD/DL650ELCD/DL850ELCD ensures consistent power to your computer system and its included software will automatically save
your open files and shutdown your computer system during a utility power loss.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral equipment does not exceed
450VA//650VA/850VA.
2. Ensure that the equipment plugged into the battery power-supplied/surge outlets does not exceed the UPS unit's rated capacity
(450VA/270W for DL450ELCD, 650VA/360W for DL650ELCD, 850VA/490W for DL850ELCD). If the rated unit capacities are exceeded, an
overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that
the battery's maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply
leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive,
Tape drive, etc.) into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or
other large electrical device into the UPS. The power demands of these devices will overload and possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker
and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc.) Avoid using extension cords.
4. Depress the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at
least one piece of equipment from the outlets. Wait 10 seconds. Make sure the circuit breaker is depressed and then turn the UPS on.
6. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically recharge.
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to
ensure battery life.
BASIC OPERATION
DESCRIPTION
Power On/Off Switch
Press the power switch to turn the UPS ON or OFF.
LCD Function Selected Switch
Press the LCD function selected switch to know the UPS status.
LCD Display
The LCD will display the UPS status including input voltage, output voltage, runtime, percentage of load and battery, etc.
AC outlet
The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges
and spikes.
USB Port to PC
Input Circuit Breaker
The Circuit Breaker provides optimal overload protection.
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
UPS Status Display
Select SW
Press
Initial
V
X
--
X
1st
V
X
--
X
2nd
V
X
--
X
3rd
V
X
--
X
4th
V
X
--
X
5th(Return)
V
X
--
X
Press >3sec
V
X
V
X
(Sound Disable)
Press >3sec
again
V
X
X
X
(Sound Enable)
(Overload)
V
X
--
V
"V" : Illuminated,
Battery mode
UPS Status Display
Select SW
Press
Initial
X
V
--
X
1st
X
V
--
X
2nd
X
V
--
X
3rd
X
V
--
X
4th
X
V
--
X
5th(Return)
X
V
--
X
Press >3sec
X
V
V
X
(Sound Disable)
Press >3sec
again
X
V
X
X
(Sound Enable)
(Overload)
X
V
--
V
"V" : Illuminated,

TECHNICAL SPECIFICATIONS

Model
DL450ELCD
Capacity (VA)
Capacity (Watts)
Input
Frequency Range
Output
On Battery Output Voltage
On Battery Output Frequency
Overload Protection
Surge Protection
Lightning / Surge Protection
Physical
Total # of UPS outlets
Maximum Dimensions (DxWxH)
Weight (kg)
Battery
Sealed Maintenance Free Lead
12V / 3.6Ah x1
Acid Battery
Typical Recharge Time
Status Indicators
Indicators
Audible Alarms
Environment
Operating Temperature
Communication
PowerPanel® Personal
Edition Software
Relative Humidity
Management
Auto-Charger
Auto-Restart
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
CyberPower's Green Commitment
CyberPower is dedicated to the development of green products, and has adopted Green practices throughout its
business, including: membership in Climate Savers Computing Initiative (CSCI), accordance with the Restriction on
Hazardous Substances (RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols, as well as ISO 14001
and IECQ QC080000. CyberPower pledges to provide the advanced energy solution for the environment and become
a leading eco-friendly organization in the UPS industry.
TM
Reduce Energy Cost with GreenPower UPS
Technology
CyberPower's goal is not only to provide eco-friendly products but also to bring the best value for consumers. The advanced energy-saving
design improves the operating efficiency and eliminates waste energy consumption. As a result, consumers will enjoy significant energy cost
TM
savings with the adoption of GreenPower UPS
technology.

TROUBLESHOOTING

Problem
Possible Cause
The outlets stop providing power to
Circuit breaker has tripped
equipment. Circuit breaker button is
due to an overload.
projecting from the side of the unit.
Battery not fully charged.
The UPS does not perform
expected runtime.
Battery is slightly worn out.
The on/off switch is designed
to prevent damage by rapidly
turning it off and on.
The UPS will not turn on.
The battery is worn out.
Mechanical problem.
Additional troubleshooting information can be found at
www.cpsww.eu
For more information, visit
www.cpsww.eu
or contact
CyberPower Systems, Inc.
All rights reserved. Reproduction without permission is prohibited.
Capacity Display
Digital Value Display
Load
Battery
Run
Input
Output
Cap.
Cap.
Time
Voltage
Voltage
V
X
V
V
X
V
V
X
X
V
V
X
V
V
X
V
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
"X" : Not Illuminated,
"--" : Either
Capacity Display
Digital Value Display
Load
Battery
Run
Input
Output
Cap.
Cap.
Time
Voltage
Voltage
X
V
V
X
V
V
V
X
X
V
X
V
V
X
V
V
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
"X" : Not Illuminated,
"--" : Either
DL650ELCD
DL850ELCD
450
650
270
360
47~63Hz (Auto Sensing)
Simulated Sine Wave at 230Vac +/-7%
50/60Hz +/-1%
On Utility: Circuit Breaker and Internal Current Limiting
On Battery: Internal Current Limiting
Yes
3 Battery Backup & Surge Protected Outlets
235 x 90 x 190mm
2.2
2.9
12V / 4.5Ah x1
12V / 7Ah x1
8 hours
LCD
On Battery, Low Battery, Overload
0C to 40C
Windows 7/Vista/XP/2000/Server 2003, Linux
0 to 90% (Non-condensing)
Yes
Yes
Solution
Turn the UPS off and unplug at least one piece of
equipment. Reset the circuit breaker by depressing the
button, and then turn the UPS on.
Recharge the battery by leaving the UPS plugged in.
Contact CyberPower Systems about
replacement batteries at
www.cpsww.eu
Turn the UPS off. Wait 10 seconds and then turn the
UPS on.
Contact CyberPower Systems about
replacement batteries at
www.cpsww.eu
Contact CyberPower Systems at
www.cpsww.eu
%
%
of
of
Load
Batt.
V
V
--
--
--
--
--
--
%
%
of
of
Load
Batt.
V
V
--
--
--
--
--
--
850
490
3.1

Advertisement

loading

This manual is also suitable for:

Dl650elcdDl850elcd