Troubleshooting Guide - Hunter PRO-C Owner's Manual And Installation Instructions

Pcc series controller 6- and 12- station indoor/outdoor, residential and light commercial irrigation controller
Table of Contents

Advertisement

Troubleshooting Guide

Problem
The controller repeats itself or
continuously waters, even when it
should not be on (cycling repeatedly).
There is no display.
The display reads "SP ERR."
The display reads "P ERR."
The display reads a station number and
ERR, such as "2 ERR."
The display reads "NO AC."
36
Cause
Too many start times (user error).
Check AC power wiring.
Electrical noise is entering the system.
There is a fault in the pump start,
master valve, or the wiring for the
pump start/master valve.
There is a fault in the station solenoid,
or the station wiring.
There is no AC power present
(the controller is not receiving power).
Solution
Only one start time per active program
is required. Refer to "Setting Program
Start Times" on page 20.
Correct any errors.
Check the SmartPort
wiring harness.
®
Verify that the red wire is attached to the
AC1 terminal, the white wire to the AC2
terminal and the blue wire to the REM
terminal. If the wires were extended then
they will need to be replaced with shielded
cable. Contact your local distributor for
information on shielded cable.
Check the master valve or pump start
wire for continuity. Replace or repair
the shorted wire. Check that all wire
connections are good and watertight.
Check the station wire for continuity.
Replace or repair shorted wire. Check
that all wire connections are good
and watertight.
Check to see if the transformer is
properly installed.