Table Of Contents; General; Shipment Inspection; Pumped Liquids - Grundfos ALPHA series Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Original installation and operating
instructions.
CONTENTS
1.
2.
3.
4.
5.
6.
6.1
6.2
7.
8.
9.
10.
11.
12.
13.
Warning
Prior to installation, read these
installation and operating
instructions. Installation and
operation must comply with
national, state, and local regulations
and accepted codes of good
practice.

1. General

Grundfos Alpha is suitable for systems with
constant or variable flows where it is desirable to
optimize the setting of the pump duty point .

2. Shipment inspection

Examine the components carefully to make sure
no damage has occurred to the pump during
shipment. Care should be taken to ensure the
pump is NOT dropped or mishandled. Check to
see that these are included:
One Grundfos Alpha pump
One line cord or terminal box
Two gaskets
One installation and operating instructions
One check valve
One "Check Valve Installed" sticker
4

3. Pumped liquids

Warning
The pump must not be used for the
transfer of flammable liquids such
Page
as diesel oil, gasoline, and similar
4
liquids.
4
Pump not for pool or marine use.
4
Grundfos Alpha is designed for pumping clean,
thin, non-aggressive and non-explosive liquids,
4
not containing solid particles, fibers or mineral oil.
5
For glycol usage as well as additional liquid
5
information see Section 10. Fault finding.
5

4. Pump installation

6
6
Warning
6
Do not energize pump until properly
installed.
7
Risk of electric shock - this pump
8
has not been investigated for use in
swimming pool or marine areas.
8
When making piping connections, be sure to
9
follow piping manufactures recommendations
10
and all code requirements for piping material.
10
System should be properly flushed of debris
before pump installation.
Insert check valve only if required; see fig. 1 .
Arrows on the pump housing indicate the
liquid flow direction through the pump.
Install the pump with the motor shaft
horizontal; see fig. 2.
Fit the two gaskets supplied to pump ends.
Fig. 1
Check valve installation
Fig. 2
Installation positions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents