LC-32LE345T
5. Signal adjustment
5.1. VCOM adjustment
Adjustment item
Adjustment conditions
1
Adjustment
[Signal]
Flicker Pattern
(2H Checkered Pattern
(2n+1))
LEVEL 1/2MAX
With Hiraki Panel Condition
2
Manual VCOM
adjustment
Input Flicker pattern
RGB 2H+1 checkered pattern
1) Adjust the VCOM value by volume resistor (VR) on SC-PWB with screw driver.
2) Revolve the VR till the flicker become the weakest.
5 – 3