Function Setting; Indoor Unit - Fujitsu ASU18RLB Service Instructions Manual

Split type room air conditioner wall mounted type inverter
Hide thumbs Also See for ASU18RLB:
Table of Contents

Advertisement

3-1. FUNCTION SETTING

3-1-1 INDOOR UNIT

Follow the instructions in the Local Setup Procedure, which is supplied with the remote control,
in accordance with the installed condition.
After the power is turned on, perform the Function Setting on the remote control.
The settings may be selected between the following two: Function Number or Setting Value.
Settings will not be changed if invalid numbers or setting values are selected.
Function Details
1-1. Setting the Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according
to the estimated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function Number
11
1-2. Setting the Auto restart
Enable or disable automatic restart after a power interruption.
Function Number
40
Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external device.
1-3. Setting the Room temperature sensor switching
(Only for Wired remote controller)
When using the Wired remote controller temperature sensor , change the setting to "Both" (01).
Function Number
42
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
Remote controller sensor must be turned on by using the remote controller.
Setting Value
00
01
Long interval (1000 hours)
02
Short interval (200 hours)
03
(
Setting Value
Setting Description
00
01
(
Setting Value
Setting Description
00
01
03-01
(
Factory setting)
Setting Description
Standard (400 hours)
No indication
Factory setting)
Enable
Disable
Factory setting)
Indoor unit
Both

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aou18rlbAsu24rlbAou24rlb

Table of Contents