Setting The Dip Switch - GE Interlogix KTC-511P Installation Instructions And Owner's Manuals

Ge series of cameras
Table of Contents

Advertisement

Note: Figure 4 and Figure 5 show connections for the pins on the solder side of the lens plug.
NC (no
connection)
Black
(ground)
Figure 4. Video-type auto iris lens leads
• For auto iris lens with built-in EE amp, follow the connections in Figure 4. (Refer to the lens
instructions.)
• For auto iris lens without EE amp, follow the connections in Figure 5. (Refer to the lens
instructions.)
1.1
S
ETTING THE
Set the DIP switch for your camera situation (see Figure 6 and Table 1).
Figure 6. DIP switches for colour
cameras
Red
(12 VAC
power)
White
(video)
DIP S
WITCH
Table 1. DIP switch settings
ATW/AWB
BLC ON/OFF
NAGC/SAGC
R = .45 / r = 1
L-LOCK/INT
Day/Night camera only:
AUTO/MAN
DAY/NIGHT
Installation Instructions
Damping
coil (+)
Driving
coil (–)
Figure 5. DC-type auto iris lens leads
Auto-tracking white balance / auto
white balance (if applicable)
Automatic backlight on or off
Automatic gain control normal (30
dB) or super (36 dB)
Gamma equals .45 or 1
Line-lock or internal synchronisation
Switches between automatic and
manual mode
In manual mode, the camera is set
manually for day or night conditions
Damping
coil (–)
Driving
coil (+)