How the air purifier works
The air purifier uses the internal fan to intake the air in the room through the intake port and discharges the air through
the exhaust port after cleaning the air is passed through the internal filters (deodorization filter (stamina-power carbon)
and dust collection filter (HEPA filter). The unit then repeats this process. During a single pass through the dust
collection filter, 99.999% of large-size dust (0.3m) can be removed. (Dust collection efficiency of the HEPA filter by
itself.) Odor ingredients are removed by repeatedly passing them through the deodorization filter for gradual adsorption.
(At this time, the dust collection filter also adsorbs odor ingredients.)
For understanding the product
Some of the odor ingredients absorbed by the filters become separated and are discharged through the exhaust port as
odor. Depending on the usage environment, this odor may become strong in several months and the exhaust port may
smell. In this case, replace the filters.
Type
Power supply
Air flow adjustment
Power consumption (W)
Air flow (m
3
/hour)
Fan rotation speed (rpm)
Noise (db)
Applicable floor area
1
Dust correcting method
Protective devices
Control panel
Indication lamp
Remote control
Outside dimension (mm)
Weight (kg)
Cord length (m)
Installation
Accessories
Replace the filter
2
Option
1: Based on the standard of The Japan Electrical Manufacturers Association, JEM1467
The size of the room to be referred to is the one in which dust concentration of 1.25mg/m3 may be reduced to
0.15mg/m 3 within 30 minutes under the condition that the natural ventilation is performed once per hour.
2: Based on the standard of The Japan Electrical Manufacturers Association, JEM1467 Ten cigarettes are smoked
per day in the place where the air cleaner is installed.
Reduction of stand-by power consumption
While this product is plugged in, it consumes the stand-by power of approximately 0.8W to activate the electric circuit

FOR EFFECTIVELY USING THIS PRODUCT

SPECIFICATIONS

FU-40SE-TA
220 V 50Hz
Max
High
39
21
240
180
1000±10
810±20
48
41
around ~ 31m
2
Mechanical purification
Temperature fuse
Motor temperature (112°C) OFF
Current fuse
Turning off when abnormal current (2.5A) flows
ON/OFF
Operation mode
ON/OFF, Tobacco, Pollen, AUTO, Air flow indication (Max., High, Median, Silent)
Air pollution level
It displays Clean sign
When clean [Green]
OFF TIMER operation A green lamp lights up at the time of off-timer operation. (1 hours, 2 hours, 8 hours)
Filter exchange lamp
Total operation time lights up in 21600 hours (one-day 12-hour x five years)
Operation mode
Manual, Auto, Silent, Rapid, Tobaccos, Pollen, OFF Timer, ON/OFF
Filter reset, Plasma cluster (Auto, OFF, Clean, Refresh)
OFF TIMER time
1 hours, 4 hours, 8 hours
415 (W) x 197 (D) x 572 (H) [When a stand is attached]
6.6
2.5
Desk top, Wall tapestry
Operation manual, HEPA filter, Remote controller, Deodorization filter
Batteries (size R6(AA) manganese batteries, Stand, Screws (2 pieces)
HEPA filter : approx. 5 years, Deodorization filter : approx. 5 years
Replace filter : FZ-40SEF (A HEPA filter and a deodorization filter are included)
Median
10
117
620±20
35
Dirt condition (Min.) [Orange]
4
Silent
4
30
260±20
16
Dirt condition (Max) [Red]