Service Manual Chapter 1 Flo-Gard 6301 Dual Channel Volumetric Infusion Pump Product Code: 2M8064 PUMP PUMP BACK LIGHT SILENCE ALARM PUMPING ALERT ALERT PUMPING ALARM NEXT TOT VOL STATUS TO ENSURE TO ENSURE PROPER SET PROPER SET CLEAR TOT VOL...
Page 2
Baxter. This manual and any information contained within, may not be reproduced, distributed, or transmitted in any form, or by any means, for any purpose, without the express written permission of Baxter. To order additional copies of this manual, or other related manuals, contact your local Baxter Service Center.
Configuration Option Feature ......Overview ........................ 5-1 Reviewing the Configuration Option Settings............5-1 Modifying the Configuration Option Settings............5-2 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 4
Separation of Front and Rear Housings ............8-5 Separation of Printed Circuit Boards ............8-7 Replacement of Front Panel Film ............... 8-8 Replacement of Pump Head Door Cover............ 8-9 Replacement of Pump Door Latch ............8-10 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 5
Calibration of Output Current Limit by VR2 ..........9-3 Calibration of Output Current Limit by VR1 ..........9-4 Safety Slide Clamp Mechanical Calibration............9-4 Air Sensor Calibration .................... 9-6 Downstream Occlusion Sensor Calibration............9-8 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 6
Theory of Operation ........12-1 Overview ......................12-1 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Table 11-18 Parts List for Accessories and Options ..............11-46 Table D-1 Multiple Key Combinations..................D-1 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
The pump operates on standard 115 VAC 60 Hz electrical power, or on its self-contained rechargeable battery. It is portable and has a panel lock-out feature to prevent tampering. It is designed for use with Baxter’s standard administration sets that contain an “s” as the last character of the code number, for example, 2C5537s.
Baxter device means that person or entity is the manufacturer of that device. Any liability arising from the use of non-Baxter parts is assumed by the entity performing such work. Baxter’s warranty is immediately null and void where non-Baxter parts are used to repair Baxter devices.
Page 17
Tighten fasteners to the torque values specified in the procedures. Do not CAUTION overtighten any fastener. Ensure that connectors are mated and observe the correct orientation. CAUTION 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Baxter’s sole obligation shall be limited to repair or replacement, at Baxter’s option and expense, of the defective part or unit, excluding batteries, for a period of one year following the date of initial delivery.
Introduction General Information Shipping costs for all units returned to Baxter shall be paid by the customer. The unit must be packed in its original container or in another Baxter approved container that provides adequate protection during shipment. Before shipping any unit for repair, call 1-(800)-THE-PUMP and notify a customer service representative to ensure prompt return of your pump.
Page 20
General Information FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
1 to 1400 mL/hr using a fully charged battery Battery Recharge 8 hours for 80% recharge 16 to 72 hours for full charge, depending upon battery condition AC Power Requirements 110/120V, 60 Hz 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
When the word “device” is used in this manual, it refers to the entire FLO-GARD 6301 Dual Channel Volumetric Infusion Pump. Generally, the word “pump” is used to refer to either Pump 1 or Pump 2.
Resets the total volume delivered to zero when the pump is stopped. 14. TIME Key Enters desired time interval for an infusion during Volume-Time or Rate-Time programming. 15. PRI RATE Key Allows programming of the primary infusion rate. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 24
Allows programming of the secondary infusion rate. 26. Numerical Keypad The numerical values for rate, VTBI, and time are entered with these keys. 27. OPTIONS Key/Legend Enables the device to operate in special modes. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
It prevents damage to the mechanism during shipment and maintains the proper spring tension. If your hospital does not plan on using the slide clamp feature, Baxter recommends that this plastic insert remain in place during use. See “Spring Retainer Removal” on page 8-22.
Description Controls and Indicators Door latch Door latch area Figure 2-2 Pump With Door Open 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
PORT communications. See the Technical Specifications listed previously in this section. 9. Volume Knob Adjusts loudness of audible alarm and alert tones. The audible alarm cannot be turned completely off. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
The tests listed below were performed at the factory. Functional Inspection 1 • LCD/LED Inspection • Main and backup lithium battery current • Battery low (alarm/alert) • Voltage • Internal inspection • Set time and date 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
To charge the batteries, plug the pump into a hospital-grade AC outlet. Verify that the Plug icon lights. Testing New and Recently Serviced Pumps Before placing new and recently serviced pumps into service at your facility, perform the following tests: FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
“Measurement by volume per time” on page 10-13 “Measurement incorporating VTBI option” on page 10-13 If the pump fails to pass any of the tests, contact your Baxter customer representative. If you want to perform additional testing before placing pumps into service, refer to the complete Operational Checkout provided in Chapter 10, “Operational Checkout”.
Terminal Strip PUMP PINOUT RY-NO RY-NO Not Used Not Used RY-NC RY-NC Not Used Not Used Not Used Not Used RY-COM RY-COM SHIELD Ground Figure 4-1 Nurse Call Cable Wiring 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
SEC START setting, in the order shown in Table 5-1, starting with Occlusion Alarm Level. To exit the inspection mode, press the key or press STOP TIME simultaneously. TOT VOL/STATUS 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Configurable Settings Factory Parameter Description Setting Options Settings 1. Alarm Log: Clear alarm/failure codes of Pump 1 or Pump 2. Select 1 or 2 to clear the corresponding pump’s alarm log. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 39
999, the maximum secondary rate matches the value of the maximum primary rate. 10. Maximum VTBI: The maximum volume that either pump can be 1 - 9999 mL 9999 mL programmed to infuse. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 40
1.09 or later. and the message INSERT SLIDECLAMP is displayed. The pump continues pumping. 3: ALARM (An audible alarm occurs and the message INSERT SLIDECLAMP is displayed. The pump does not operate.) FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 41
18. Time Setting: Set the real time clock in hours and minutes (military —— Central time 00:00 - 23:59). Standard Time-CST 19. Date Setting: Set the date using the Month/Day/Year format. —— Current date-CST 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 42
Modifying the Configuration Option Settings FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Overview This chapter contains a table describing preventive maintenance which should be performed on the FLO-GARD 6301 Dual Channel Volumetric Infusion Pump. The maintenance procedures outlined in this section may be performed in the hospital. When an abnormal condition occurs which is not correctable by performing the following procedures, remove the pump from service and troubleshoot it in accordance with Chapter 7, “Troubleshooting”, or return it...
Clean all surfaces in the pump head which may contact the tubing. Clean all surfaces of the air sensor located just above the safety clamp. This area must be completely dry and free of foreign matter prior to reuse. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
“Calibration”. Main Battery Recharge by plugging into a 115 VAC outlet for at least 16 hours. Check that the Plug Icon is illuminated during this time. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 46
Schedule: Every 6 months or as required Battery check Perform the Battery Check described in Chapter 10, “Operational Checkout” every 6 months after the first year following battery installation/ replacement. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
When troubleshooting the pump, do not inject or apply signals unless the CAUTION procedures herein specifically instruct you to do so. Damage to the pump or its subassemblies could result. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
OF CHAPTER 10 PUMP PERFORMANCE PLACE PUMP IN ACCEPTABLE SERVICE TROUBLESHOOT IN ACCORDANCE WITH CHAPTER 7 REPAIR IN ACCORDANCE WITH CHAPTER 8 RECALIBRATE IN ACCORDANCE WITH CHAPTER 9 Figure 7-1 Maintenance Flowchart FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Table 7-1 the alarms and the possible causes of each. In all cases, fluid infusion is halted. Appropriate troubleshooting is discussed throughout the rest of this chapter. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
To clear this alarm, open the pump door and insert the Note: This alarm option is available slide clamp into the slot. Close the door. only on pumps running software versions 1.09 or later. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
PRI or SEC Enter a rate within the range selected through the configuration option. The pump cannot be START started when Hi or Lo is displayed in a rate display. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
CLR to erase the profile; press NEXT to review the rest of the profile; press PRI RATE or PRI VTBI to modify this step; press OPTIONS to leave the PDP mode. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
“Automatic Test Mode 2: Calibration Mode 2” on page 9-16, respectively). Modes 3 through 10 are described briefly in the following paragraphs. The procedure to access any of the automatic test modes is as follows: 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
The pump stops automatically one hour after the key was PRI START pressed. While the pump is running, the air sensor and the upstream and downstream occlusion sensors are disabled. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
After exiting test mode, the downstream occlusion sensor level reverts to the original configuration setting. Rate and VTBI information may be programmed manually. 7-10 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Perform “Automatic Test Mode 1: Perform “Safety Slide Clamp Calibration Mode 1” on page 9-14, Mechanical Calibration” on page steps 1 through 9. 9-4. 7-11 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 58
Ensure communication cable is PC for a given period plugged in and/or the cable is wired correctly. Correct problems with PC software. 7-12 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 59
Check connector CNBUS1/ Repair or replace CNBUS1/ agree. CNBUS2 for proper connection CNBUS2 if necessary. and continuity. Replace CPU board. Replace Sensor board. Failure in occlusion circuit. None Replace CPU board. 7-13 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 60
Check that front panel is panel. not damaged. Master CPU received an abnormal Check HIC302 on CPU board for Replace CPU board. power ON/OFF signal. proper function. 7-14 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 61
Turn pump off and back on. If failure recurs, replace CPU interrupt. board. Master CPU received an OCI Turn pump off and back on. If failure recurs, replace CPU interrupt. board. 7-15 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 62
8 and 9 did not complete Replace Sensor board. in 72 μS. Abnormal battery recharging Check calibration of DC Power Recalibrate the board. If failure voltage. Supply board. recurs, replace CPU board. 7-16 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 63
Replace Sensor board. mounting. Replace CPU board. No acknowledgment message Turn pump off and back on. If failure recurs, replace CPU from Slave CPU for three board. communication trials. 7-17 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 64
Turn pump off and back on. If failure recurs, replace CPU board. Undefined failure code received Turn pump off and back on. If failure recurs, replace CPU from Slave CPU. board. 7-18 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Pressing a START key causes a Power the pump off and on again. If the problem persists, recharge the BATTERY LOW alarm. battery. Repair as required. If the problem persists, replace the battery. 7-19 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 66
Replace CPU board. The backlight is off when the pump is Press the BACKLIGHT key as long as running on internal battery power. required to view the pump settings. 7-20 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 67
Check CNDISP for proper connection Replace Sensor board. and continuity. Replace Display board. PUMPING LED(s) do(es) not light. Check CNDISP for proper connection Replace Sensor board. and continuity. Replace Display board. 7-21 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 68
Backup buzzer does not activate Check that the buzzer wiring is Plug in connector. during self test. connected. Replace fuse. Check for an open fuse on the battery Replace backup buzzer. wire harness. 7-22 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 69
Clean the sensor with cotton swabs dampened with one of the agents listed in Table 6-1. Remove fibers or foreign particles. Do not use hard instruments for cleaning. 7-23 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 70
Check for worn or missing friction Replace worn or defective parts on the on the IV pole. pad. clamp as necessary. Check the clamp for worn threads and other worn or defective parts. 7-24 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 71
60° and Raise or lower the temperatures. 100°F (15.5° and 37.7°C). Replace broken parts if required. Check for broken safety clamp spring and/or broken safety clamp. 7-25 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 72
Verify air sensor calibration in accordance with “Automatic Test Mode 2: Calibration Mode 2” on page 9-16 steps 2 through 9. Repair or replace the occlusion sensor. 7-26 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 73
The interval between audible alarm Change the interval for alert and/or tones is too long. alarm tones to the desired value through the configuration option. 7-27 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Any liability arising from the use of non-Baxter parts is assumed by the entity performing such work. Baxter’s warranty is immediately null and void where non-Baxter parts are used to repair Baxter devices.
NEXT SEC START sequentially. Record the configuration settings. Exit the configuration inspection mode by pressing TIME TOT VOL/ again or press Pump 2’s key. STATUS STOP FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Item 25 in Figure 11-4 7 kgf-cm (6.1 in-lbs) Disassembly/Reassembly Disassembly of the FLO-GARD 6301 Dual Channel Volumetric Infusion Pump is limited to the field replaceable units (FRUs) as shown in the figures in Chapter 11, “Illustrated Parts Breakdown”. Use only the approved replacement parts listed in Chapter 11, “Illustrated Parts Breakdown”.
Make sure that the connector flange is unlocked and reconnect the ribbon cable connector CNI/F on the CPU PCB. Push in the flange to hold the ribbon cable in place. Reconnect CN1 on the power supply board. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 80
7.17 them to 9 kgf-cm (7.8 in-lbs) with a torque screwdriver. Perform the Operational Checkout procedures in Chapter 10, 7.18 “Operational Checkout” if no other repairs are to be performed. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
The function of the four printed circuit boards can be checked outside of the front housing as long as all the connectors are properly connected. Perform the Operational Checkout procedures in Chapter 10, “Operational Checkout”. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
40 to 50 seconds per edge. Remove the masking tape before the silicone starts to form a skin. Keep the pump on its back for 30 – 45 minutes. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Proceed to the next step. 3.10 Note: If this does not stop the clicking you need to check for the source in other areas such as a loose motor coupling or a misaligned motor. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
(item 6), and the other thin washer (item 8) on the door latch pin. Insert the pin into the hole in the pump door. Open the pump door slightly. 8-10 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Calibrate in accordance with “DC Line Voltage Calibration” on page 9-1 through “Downstream Occlusion Sensor Calibration” on page 9-8. Perform the Operational Checkout procedures in Chapter 10, “Operational Checkout”. 8-11 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
CAUTION be torqued to 9 kgf-cm (7.8 in-lb). The screw (Figure 11-2 , item 13) for the pump head ground wire must be torqued to 7 kgf-cm (6.1 in-lb). 8-12 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Calibrate in accordance with “DC Line Voltage Calibration” on page 9-1 and “Upstream Occlusion Sensor Calibration” on page 9-10. Perform the Operational Checkout procedures in Chapter 10, “Operational Checkout”. 8-13 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Be sure not to cut or nick any other wires during this process. Removing two cable ties usually frees the cable but, in some instances, more need to be removed. They are replaced with new cable ties upon completion of these steps. 8-14 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
“Operational Checkout”. Replacement of Force Sensing Resistor (FSR) Devices for Tube Misloading Sensors Note: When the repair requires replacement of the FSR, replace the pair of FSRs. 1. Interlink Electronics 8-15 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 90
Loosely attach a new tube misloading sensor to the pump base plate. Ensure that it fits within its recess and does not override the pump head area. Do not attach the sensor firmly to the pump base plate yet. 8-16 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Carefully remove the two springs (Figure 11-8 or Figure 11-13 , item 9) above the motor coupling. Remove two screws (Figure 11-9 or Figure 11-14 , item 30) that secure the motor holding plate to the safety/slide clamp assembly. 8-17 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 92
Be sure that the fingers are in the finger box and the motor 18.2 holding plate is properly installed in the groove of the safety/ slide clamp assembly (Figure 11-8 or Figure 11-13 , item 1). 8-18 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Separate the front and rear housings in accordance with “Separation of Front and Rear Housings” on page 8-5. Remove the pump motor in accordance with “Replacement of Pump Motor” on page 8-17. 8-19 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 94
Inspect for a white or yellow dot on the side of the slide clamp assembly (nearest the middle of the device) and on the FPC terminal PCB (see Figure 8-2 for location). If a dot is present, proceed to step 15. 8-20 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Instructions for installing the spring retainer are provided below. 8-22 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Press the back plate a few times from the inside of the door to ensure smooth operation. Tighten the screws to 6 kgf-cm (5.2 in-lb). 8-23 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Be careful not to pinch wires between the front housing and battery compartment CAUTION cover. Be sure to place the battery cover seal (Figure 11-4 , item 13) appropriately in the CAUTION groove located on the rear housing. 8-24 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
(Figure 11-3 , item 1) between the power supply board and the bosses for it. Tightening torque for the four screws (Figure 11-3 , item 21) securing the board is 7 kgf-cm (6.1 in-lb). Connect CN1. 8-25 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Stand the printed circuit cards upright and remove the five screws (Figure 11-2 , item 15) securing the corners and right center of the display board. Carefully disconnect connector CNDISP and remove the display board from the sensor board. 8-26 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
(item 2) to the rear housing. Remove the board. Reassemble in reverse order. Tightening torque for item 21 is 7 kgf-cm (6.1 in-lb). Perform the Operational Checkout procedures in Chapter 10, “Operational Checkout”. 8-27 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Route the wires underneath the transformer mounting bracket (Figure 11-3 , item 8) and the insulation film (Figure 11-3 , item 24) under it before replacing the bracket.) 8-28 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Separate display board in accordance with “Replacement of CPU Board” on page 8-26. Cut the tie wrap holding the lithium battery on the display board (Figure 11-2 , item 2). Disconnect connector CN304 and remove the lithium battery. 8-29 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Prism 454 adhesive to the tube guide surfaces to which the shim is to be bonded. To achieve a good bond you must apply adhesive to all of the shaded areas (see Figure 8-3). 8-30 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Pump 1. Figure 8-5 LCD Cushion Placement (Inside View) Note: The LCD cushion is installed on the inside of the case housing not on the LCD. 8-32 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Turn off the pump and disconnect it from AC power. Remove the four corner screws (Figure 11-4 , item 26) that hold the battery access cover (Figure 11-4 , item 3) in place. 8-33 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
The recessed area in the housing for the pole clamp body must be clean. The three mounting screw holes in the housing must not show signs of cracking. The ground wire must be attached to the center screw. 8-34 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 109
If not already present, apply an upgrade label (Part no. 072601047) between the feet on the front case half. Use indelible ink (permanent marker) and mark box number 2. Perform the Operational Checkout procedures in Chapter 10, “Operational Checkout”. 8-35 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Pin 8 (top pin) of the CNTEST1 connector is signal ground. Connect a voltmeter to Vmain (pin 6) with the pump powered off, the reading should be: 13.65 ±0.15 VDC 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Digital voltmeter: 4.5 digits with ±0.1% accuracy at 20 VDC range and ±3% accuracy at 100 - 135 VAC range. • DC ammeter: 2 ADC in 0.01 A increments. • Resistive load as shown in Figure 9-1 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Adjust the variable transformer output to 120 VAC. The 14.9 voltage may be checked with an ordinary tester with ±3% accuracy. Adjust the potentiometer until the output current is 1.40 A. 14.10 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Lay the 0.045 in. (1.15 mm) pin gage in the section of the pump head as shown below. Make sure that the end of the pin gage extends about 1/4” from the bottom of the pump head. FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
If no excess shims or damage are noticed, replace the safety clamp plate with a thinner plate (part no. S054643) and retest. If excess shims are installed, remove one and retest. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
If the white tubing guide shim or letter “A” is not present, go to “Tube Guide Shim Installation” on page 8-30 to install the tubing guide shim. For FLO-GARD 6301 pumps with serial numbers less than 83030018 but not ending in FA, a modification to the air sensor assembly is also necessary.
Page 117
Open and close the pump door two more times and wait 2 minutes. Verify that both NORM and MIN values are within the range of 410 and 470. Note: Apply Red Glpt to VR801 and VR802. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Exit Test Mode 2 by pressing the key. ON-OFF/CHARGE Prime and load a Baxter “s” suffix standard administration set. See “Administration Set Preparation” on page 10-2, steps 1-6. Using the precision syringe, introduce an air bubble (25 μL for MIN setting, or 50 μL for NORM setting) into tubing just above the pump...
Page 119
Failure Identification Code appears in the lower right corner of the Main Display. The Failure Identification Code should be 2 or 3. Turn off the pump and reassemble the pump door cover. 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Install the pump head door cover. See “Replacement of Pump Head Door Cover” on page 8-9. Turn off the pump. 2.10 The following procedure confirms that the calibration is correct. 9-10 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Use a cotton-tipped swab dampened with water to clean the safety clamp sensor. This sensor is located approximately 1/4” in at the upper left of the slide clamp slot. Repeat with a second dampened swab. 9-11 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 122
(“Replacement of Safety/Slide Clamp Assembly” on page 8-19). Apply a thin film of Red Glpt to VR802 to lock it in position. Perform the Operational Checkout procedures in Chapter 10, “Operational Checkout”. 9-12 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
NORM and MIN Air Sensor Calibration with Air Filled Tubing NORM < 11 NORM and MIN Air Sensor Calibration with No Tube NORM < 40 FSR Verification with Pump Door Open RIGHT 500-820 LEFT 9-13 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
If the value is within specification, proceed to the next step. If the value is out of specification, perform “Upstream Occlusion Sensor Calibration” on page 9-10, steps 2 and 3. 9-14 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 125
“DC Line Voltage Calibration” on page 9-1. If the MB display is within specification as described in step 10, the main battery should be replaced per “Replacement of Battery” on page 8-24. 9-15 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
If the pump is not in Test Mode 2, turn off the pump and repeat this step. Load a Baxter “s” suffix standard administration set and prime it with fluid. Close the pump door. Ambient and solution temperatures must be between 72°...
Page 127
Follow steps 14 through 18 to check that the tube misloading sensor outputs in SEC RATE and SEC VTBI windows are within specification. Load a Baxter “s” suffix standard administration set and prime it with fluid. With the pump door open, check the FSRR value (at SEC RATE window) and the FSRL value (at SEC VTBI window).
Turn the pump on and adjust potentiometer VR501 until the meter reading is 5.000V ±0.010 V. Disconnect all test equipment. Install the EPROM cover and battery, see “Replacement of Battery” on page 8-24. 9-18 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
As part of a thorough checkout, verify the calibration values as indicated in Chapter 9, “Calibration”. The following test equipment is required to perform the operational checkout procedures: Baxter Continu-Flo “s” suffix administration set with at least one Y-site Secondary administration set Solution containers (such as distilled/sterile water) Precision gas-tight 250 μL syringe (Hamilton #1725 or equivalent)
Using a solution filled container (distilled/sterile water, etc.) and a Baxter Continu-Flo administration set with at least one Y-site, prepare the administration set according to instructions accompanying the set. Splice a tubing segment (part no. 03-02-92-479) into the middle of the administration set.
• The backup buzzer will turn on after the main buzzer turns off. • When the backup buzzer turns off, all LEDs will turn off. 10-3 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 132
Power on the other pump. Verify all that all segments of the Main Display LEDs are lit. Reconnect the device to AC power. Verify that the plug icon is lit and that the battery icon is OFF. 10-4 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
2 (ON or ALERT) or 3 (ALARM). If necessary, remove the spring retainer and enter the modify configuration mode to configure INS CLAMP to option 2 (ON or ALERT) or 3 (ALARM). 10-5 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 134
With the device ON, open the door and fully insert the slide clamp of a primed Baxter “s” suffix standard administration set into the slide clamp slot. Press the red safety clamp arm until it locks open, and load the set into the pump mechanism.
Chapter 8, “Removal/Replacement Procedures”. Perform this test to verify air detection. Prime and load a Baxter “s” suffix standard administration set with one Y-site above the pump. Follow “Administration Set Preparation” on page 10-2, steps 1 through 6.
Note the left and right FSR values displayed when the pump is plugged If the values are within 10 counts in the readings, proceed to the next step. If there is a jump of more than 10 counts in the readings: 10-8 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 137
Verify that the message display shows CHECK SET LOADING, the ALARM LED blinks on and off, and the audible alarm tone is sounding. Record the result on the data sheet. 10-9 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Perform the following steps at room temperature to ensure proper operation of the downstream occlusion sensor. Prime and load a Baxter “s” suffix standard administration set. See “Administration Set Preparation” on page 10-2, steps 1 through 6. Start the pump at a rate of 200 mL/hr with a VTBI of 20 mL. Allow the pump to deliver at least 5 mL.
Plug the battery into AC power for at least 16 uninterrupted hours before proceeding to the next step. Load a primed Baxter “s” suffix standard administration set into the pump. Set the pump’s PRI RATE to 1901 mL/hr and PRI VTBI to 4800 mL and start both pumps.
Accuracy Test” on page 10-14), or one of the shorter tests (“Measurement by volume per time” on page 10-13 or “Measurement incorporating VTBI option” on page 10-13). The One-Hour Accuracy Test should be performed if either of the shorter tests fail. 10-12 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
“Administration Set Preparation” on page 10-2. Note: An unused section of a Baxter “s” suffix standard administration set or calibra- tion tubing (part no. 03-02-92-479) can also be used for these tests. Mark the section of the tubing in the pump to indicate that the segment has been used.
Replace any pump head that fails this test and be sure to clearly identify it as having failed the One-Hour Accuracy Test. 10-14 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Overview This section includes illustrations and parts lists required to identify any replaceable part in the FLO-GARD 6301 Dual Channel Volumetric Infusion Pump. Each illustration is keyed to a parts list, which lists each component shown in the figure by part number and description. The quantity per assembly is also shown.
F044620002 SPRING, Retainer XBPUF30P.A 4009310009 SCREW, Pan Head, M3X20 See Figure 11-5 Pump Head with door open See Figure 11-10 Figure 11-1 Front Housing Assembly (F059990006) - Front View 11-2 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
072626932 072623932 Front Door Information Label Note: See “Safety Slide Clamp Mechanical Calibration” on page 9-4. 1, 11 15 or 32 Figure 11-5 Pump Head 1 Door Assembly (F059120016) 11-11 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 166
Plate Safety Clamp, 1.0 mm Thickness (See Note Below) Optional 072623931 072623931 Inside Door Information Label 072623932 072623932 Front Door Information Label Note: See “Safety Slide Clamp Mechanical Calibration” on page 9-4. 11-24 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
CMK-77X R19 R20 CMK-77X C2 C1 ACIN A K A A K A SCR1 Component Side V1 Q3 C1 C2 SCR1 Solder Side Figure 11-15 Power Supply PCB (RDENC100.E) 11-38 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
The master CPU also handles RS-232 serial communication with an external computer through the communication controller. The slave CPU controls the pump motors via the motor control circuit in three ways: Generates pulses to rotate the motors. 12-1 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
CPU was never received. This indicates a problem with the other CPU. The remaining functional CPU then stops the pumps with visual and audible alarms. 12-2 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
CPU and converts the following analog signals into digital signals: air sensor outputs, tube misloading sensor outputs, battery voltages, motor currents and the voltage of the CPUs. The digital signals are periodically read by the master CPU. 12-3 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
The moving ferrite core is spring loaded against the administration set. When pressure downstream of the pump increases, the core moves from its original position, which in turn changes the frequency of the oscillator. 12-4 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
CPU via the I/O controller. The CPU activates an alert or an alarm (software versions 1.09 or later) when the slide clamp is not loaded and the option has been selected. 12-5 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
I/O controller. One of eight select lines determines which four keys are read. All normal keypad depressions are decoded by this matrix except the keys, which have special inputs to the ON-OFF/CHARGE power control circuit. 12-6 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
The motor rotation signals are read by the master CPU via the UPP and slave CPU. The sector signals are read by the slave CPU and utilized for controlling motor currents. 12-7 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
The master CPU saves necessary data in the back up memory in the RAM (U507) and turns off the Vcpu, Vref and Voth voltages when both pumps are turned off. 12-8 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 197
The RAM (U006) for the slave CPU is not backed up. 12-9 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 198
DC Power Supply and Power Control Circuit 12-10 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Diagrams Chapter 13 Overview This section contains all of the schematic and wiring diagrams for the FLO-GARD 6301 Dual Channel Volumetric Infusion Pump. These diagrams are intended only to assist the reader in understanding the theory of operation. 13-1 07-19-B1-729...
Fail Mounting clamp moves freely Pass Mounting Clamp Check Fail Disc and cushion are installed correctly Power cord is secure, undamaged, and is a Baxter-approved part Fail Software Check Master Version Number: Self Test Pump 1 Power Up Self-Test completed successfully...
Page 240
(85μL) Air detected Fail Pass Pump 2 (50μL) No air detected Fail Pass NORM (110μL) Air detected Fail Pass (25μL) No air detected Fail Pass (85μL) Air detected Fail Pass FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 241
Alarm LED flashes < 3 Minutes Audible alarm sounds Pump 2 Pump stops Time to Alarm: "UPSTREAM OCCLUSION" message displays Time to Alarm Alarm LED flashes < 3 Minutes Audible alarm sounds 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 242
Multimeter Calibration Due Date/ID: _________________________________ Electrical Safety Tester Calibration Due Date/ID: _______________________________ Electrical Safety Tests Ground Impedance Ω Ω Ground Impedance < 0.5 Leakage Current Earth Leakage Current < 50 μA μA FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 243
PRI Rate 200mL/ VTBI 35mL 32.5mL-37.5mL 1 Hour Accuracy Test Note: Perform only if pump failed Volume Measurement w/VTBI or Measurement by Volume per Time N/A ______ PRI Rate 125mL/ VTBI 1000mL 116.25mL-133.75mL 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Downstream Occlusion Calibration Verification 2967-3039 Value Pump 1: Value Pump 2: Main Battery Calibration Verification 688-714 Value Pump 1: Value Pump 2: Backup Battery Calibration Verification 574-737 Value Pump 1: Value Pump 2: 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 246
FSR Verification with Tubing Misloaded Value Pump 2: RIGHT Value Pump 1: 450 or less Value Pump 2: LEFT Value Pump 1: Value Pump 2: Vcpu 472-579 Value Pump 1: FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...
Page 247
Range 1- 1999 mL/hr, record value: Maximum VTBI 9999 mL Range 1- 9999 mL, record value: Flow Check Display Baud Rate 9600 1200 2400 4800 9600 Computer Control Disabled Disabled Off w/Alarm On w/Alarm 07-19-B1-729 FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL...
Page 248
On (Software versions earlier than V1.09) Alert (V1.09 Software or later) Alarm Programmed Delivery Profile Disabled Disabled 5 Hour Memory Semi-permanent memory Time Setting Military Time record value: Date Setting 00/00/00 (mm/dd/yy) record value: FLO-GARD 6301 DUAL CHANNEL VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-729...