Install The Hood (Standard Installation) - Kenmore 51293 Use & Care Manual

Hide thumbs Also See for 51293:
Table of Contents

Advertisement

Available languages

Available languages

NOTE: Two installers are recommended because of the weight of this hood.
1. Run house power cable between service panel and
hood location. For hood with power cable access
located on back of hood, run the house power cable
into the hood through the strain relief previously
installed in step 8 on page 8. For hood with power
cable access located on top, tighten the strain relief
to the power cable before inserting the strain relief
in the knockout hole.
2. Hang hood from (2) mounting screws previously installed.
Slide hood back towards wall until mounting screw
heads are engaged in narrow end of keyhole slots in
top of hood. Tighten screws securely and maintain a
hold on the hood until completing step 3.
3. Secure the hood to the cabinet using 2 no. 8 x 5/8"
round head wood screws and 2 washers (screws and
washers included in parts bag). Insert 1 screw and
washer per side, in the slots (as shown beside. Attach
power cable to the hood using the strain relief.
4. Connect the ductwork to the hood and use metal foil duct tape to make joints secure and air-tight. Make sure
the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.

Install the Hood (Standard Installation)