Filter Flex-Hose Installation - King Technology 01-01-7820 Instruction Manual

Mineral pool-care infuzer for pools up to 25,000 gallons
Table of Contents

Advertisement

TOOLS NEEDED
Screwdriver
Pipe Wrench
INCLUDED WITH FROG Leap
Infuzer
Pipe Thread Tape
or Sealant
One 6" X 1½" TBE PVC
Nipple
MATERIALS NEEDED
One Hose Adapter
1½" X 1½" X 1¼"
One Section of
1½ or 1¼" Flex Hose
One
Hose Clamp
RECOMMENDED
4-8 psi Back Pressure
To avoid over or under chlorination,
replace eyeball fi ttings in the
return jets to a smaller or larger
size to adjust back pressure. For
best results use King Technology's
pressure gauge, order part number
01-22-4000.

Filter Flex-Hose Installation

Apply pipe thread tape or
1.
sealant to each threaded
end of nipple.
Apply pipe thread tape or
4.
sealant to threaded end of
hose adapter.
Screw one end of nipple
2.
into the fi lter return. Hand
tighten. Finish tightening by
turning 1 to 2 revolutions
with a pipe wrench.
DO NOT OVER TIGHTEN.
Screw adapter into the other
5.
side of FROG Leap Infuzer.
Hand tighten. Finish tightening
by turning 1 to 2 revolutions
with a pipe wrench.
DO NOT OVER TIGHTEN.
Screw either side of
3.
FROG Leap Infuzer on
to open nipple end until
upright and secure.
6.
Attach return section of hose to
the adapter with clamp. Tighten
clamp with screwdriver.
7.
To prevent damage to heaters
or fi lters, see your dealer about
installing a corrosion resistant
check valve which will reduce
the back fl ow of chlorine gas
when the Infuzer is turned off.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

01-12-782201-10-785801-03-7937

Table of Contents