Safety Labels on Infuzer

Review this label before installing or operating this Infuzer. Contact King Technology at 800-222-0169 if this label is missing from your FROG Leap Infuzer.
Fire, explosion and high pressure hazards
To minimize the risk of serious injury, death or property damage while using the FROG Leap Infuzer:
a Read, understand and follow all instructions and safety precautions in the manual, and on this Infuzer and on any label for chemicals used
with this Infuzer including FROG Leap Torpedo Pacs, FROG Leap Anti-Bac Mineral Pacs and FROG Leap Wake Up!/Hibernation.
a Never use fast dissolving chlorine tablets, liquid bleach, or calcium hypochlorite in the FROG Leap Infuzer.
a Never mix Trichlor chlorine tablets with Calcium Hypochlorite, or with any other form of concentrated chlorine or other chemicals.
a Never add any other types of chlorine, pH adjusters, shock treatments or algaecides through the skimmer.
These products should be added directly into the pool if required.
a Do not contaminate the FROG Leap Infuzer, Anti-Bac Mineral Pac, Torpedo Pac or Wake Up!/Hibernation (which includes Reveille, Depth Charge and ALL-OUT)
with dirt, organic matter, pool chemicals (such as calcium hypochlorite or pool shocks), fertilizers or other household chemicals. Contact between any of
these substances and the FROG Leap Infuzer, Anti-Bac Mineral Pac, Torpedo Pac or Wake Up!/Hibernation, will result in a chemical reaction with the generation
of heat, liberation of hazardous gasses and fi re or explosion.
a Use only FROG Leap Torpedo Pacs, Anti-Bac Mineral Pacs and Wake Up!/Hibernation (which includes Reveille, Depth Charge and ALL-OUT)
in the FROG Leap Infuzer. Never use bulk chemicals.
a To prevent the build up of gas pressure in the FROG Leap Infuzer, be sure the pool return line valves are open –
except when opening or servicing the unit.
a Do not inhale fumes from the FROG Leap Infuzer or FROG Leap Torpedo Pac.
a Avoid sparks, smoking, or any open fl ame near FROG Leap Infuzer or chemicals.
a Do not exceed maximum operating pressure of 50 psi or maximum temperature of 104 º F.
a Do not remove the cap while under pressure. Always turn off pump and bleed off pressure before opening FROG Leap Infuzer.
a Do not install automatic or fast shut off valves downstream of Infuzer.
a Always install the FROG Leap Infuzer AFTER a heater (if applicable) on the return line.
a Always install any additional sanitizing equipment AFTER and NEVER BEFORE the FROG Leap Infuzer is installed on the return line.
a Do not permit children to use or climb on this product. This product must be positioned to prevent children from using it as a
means of access to the pool.
a Always stand clear of the FROG Leap Infuzer during pump start-up.
a Replace FROG Leap Infuzer if you see signs of cracks, damage or degradation to the Infuzer body or cap.
a Prior to pressurizing, check with your dealer to ensure your plumbing connections meet building codes.
a Failure to properly winterize your FROG Leap Infuzer could result in freeze damage. (See page 19 for winterizing details.)
DANGER
WARNING
NOTICE
NOTICE