3g sdi frame synchronizer with up/down/cross converter and scaler (2 pages)
Summary of Contents for Lynx P DM 5240 D
Page 1
LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik AG or any of its affiliates.
LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located.
Brunnenweg 3 D-64331 Weiterstadt Germany Declare under our sole responsibility that the product TYPE: P DM 5240 D; P DM 5240 U To which this declaration relates is in conformity with the following standards (environments E1-E3): EN 55103-1 /1996 EN 55103-2 /1996 EN 60950-1 /2006 Following the provisions of 89/336/EEC and 73/23/EEC directives.
P DM 5240 Reference Manual. Rev 2.1 Getting Started Most CardModules are installed into the rack frames and system tested in the factory. If this is an upgrade part or service exchange item then the module is supplied in a padded cardboard carton which includes the CardModule, rear connection plate and mounting screws.
AES inputs or outputs. These AES ports are provided as balanced AES3 audio inputs or outputs on a 25 pin SubD connector (P DM 5240 D) and as unbalanced AES3id audio inputs or outputs on 75Ohm MiniDIN connectors (P DM 5240 U).
P DM 5240 Reference Manual. Rev 2.1 Video Input Formats The module has a multi-format serial digital input with automatic input detection. The module will detect the following input standards and configure the input stage automatically for operation in the connected format. SDTV Formats HDTV Formats 525 / 59.94Hz...
P DM 5240 Reference Manual. Rev 2.1 Audio Processing The module will de-embed the complete audio payload from the incoming SDI stream (4 AES groups = 8 AES streams = 16 mono channels), and passed to the AES audio processing infrastructure, along with up to 8 external AES inputs. The type of audio (PCM, DolbyE or Audio Data) is detected by the module automatically.
Balanced (AES3) external audio connections. The P DM 5240 U versions provides MiniDIN (DIN1.0/2.3) connections for unbalanced AES3id The P DM 5240 D versions provides a SubD25 connector for balanced AES3 (pin layout see table below and Figure 6) Pin Number...
P DM 5240 Reference Manual. Rev 2.1 Installation If this module was supplied as part of a system it is already installed in the rack enclosure. If the module was supplied as a field upgrade please follow the installation procedure below. NOTE Observe static precautions when handling card.
P DM 5240 Reference Manual. Rev 2.1 Once set, all settings are automatically saved in non-volatile internal memory. (Flash RAM) The module will always recall the settings used prior to power down. See section “Save Settings Now” on page 28 for more details. Figure 7: Card Edge switches and LED positions DIP Switch Settings...
P DM 5240 Reference Manual. Rev 2.1 DIP Switch 1 enables local adjustments. Setting it to ON enables the setting of the other DIP switches to configure the module. Setting it to OFF will prevent any local DIP switch settings from taking effect. NOTE: It is recommended to set DIP switch #1 to OFF to prevent from accidental changes to the stored module configuration if the switches are moved.
P DM 5240 Reference Manual. Rev 2.1 Alarm/LED Status Indicators LED 1: SDI Status LED Color Indication Green SDI input ok SDI ok but unsupported standard Yellow (no embedding takes place) SDI input missing LED 2: Audio Status LED Color Indication ...
P DM 5240 Reference Manual. Rev 2.1 Control System GUI All LYNX CardModules support a computer interface which allows setting the modules parameters using a simple GUI interface. Access to all standard features and in some cases extended features is possible using this interface. The complex nature and extensive user settings provided on the P DM 5240 requires the use of the control system.
P DM 5240 Reference Manual. Rev 2.1 The “Event Log” at the bottom of the screen displays an individual timestamp’ed message for any error or warning condition in the system. The same information can always be found in the APPolo Control System’s textual logfiles. The primary GUI screens and functions are described in the following sections.
The internal delay and signal timings can NOT be influenced or modified in the P DM 5240. For applications that require a manual adjustment of such delay values, consider the use of the LYNX P DM 5280 product. Audio Infastructure The complete audio payload of 8 AES is deembedded from the SDI input stream.
P DM 5240 Reference Manual. Rev 2.1 group 3, however, is not guaranteed to be phase-aligned with the content of groups 1 and 2 (which had been there before already). I.e. if the content of the HANC space is re-arranged to accommodate for an additional audio group while other audio groups remain present, the additional groups are, by default, not guaranteed to be deembedded phase-aligned to the previous content.
P DM 5240 Reference Manual. Rev 2.1 Audio Processing The Audio Processing block provides access to the detailed audio processing functionality. The following functions are available per mono-channel. Gain Adjustment [-66.3dB … +18dB] Phase Inversion [on / off] Mute [on / off] Mono Downmix per output mono-channel: enable the addition of the other (sibling) mono-channel as a simple (a+b)/2 downmix.
P DM 5240 Reference Manual. Rev 2.1 Audio Crossbars After going through the audio processing stage, each internal audio stream is delivered to the output audio crossbar. Here, each of the possible audio destinations (embedder and external output) can select from all of the available signals. The output can be connected to a new source by simply clicking onto an existing connection and dragging and connecting the open handle to the desired...
Page 23
P DM 5240 Reference Manual. Rev 2.1 An embedded audio-group can only be embedded as a complete group containing two AES streams. If you want to replace only one out of the two AES streams in the SDI, you need to feed the other AES stream from the Deemedder (on the left) through the audio- processing block and the output crossbar to the Embedder, and re-embed it together with that other (new) AES content into the same group.
Active” and “Event not active anymore” messages. Similarly, an SNMP trap can be generated from the APPolo Server for any message in the APPolo Event System. Refer to the LYNX Remote Control Guide for more information on SNMP (available from http://appolo.lynx-technik.com)
P DM 5240 Reference Manual. Rev 2.1 Parameters The “Params” tab lists all available control parameters of the complete device. Every switch and function in any other part of the GUI is actually just a graphical control of a parameter listed on this page. There are, however, a number of parameters for more detailed control that are only accessible in this list of parameters on the “Params”...
As stated above, the complete behavior of any LYNX Device can be controlled and monitored through the parameters listed on the “Params” tab. All other parts of the LYNX APPolo Control System use these Parameter to take access to any aspect of the Device.
P DM 5240 Reference Manual. Rev 2.1 General GUI functions There are a number of functions and commands of the LYNX APPolo Control System which are common for all LYNX devices. A click with the Right-Mouse-Button on any module in the DeviceTree will generate the same menu that is available from the “Device”...
(save this as an empty name). Figure 21: Rename Device NOTE: The names are stored inside the flash memory of a LYNX server (if installed) or the hard disk of the connected Computer respectively. Save Settings Now Any modification to any parameter of a device is immediately propagated from the APPolo GUI to the hardware device (card) and made effective.
P DM 5240 Reference Manual. Rev 2.1 Specifications Video Input Signal Type Signal Type Supported Formats Supported Formats Input Imedance Input Imedance Input Level Input Level Return Loss Return Loss Digital Video Ouputs Signal Signal Output Impedance Output Impedance Output Level Output Level Return Loss Return Loss...
Due to the very dense design and high level of integration there the module is not user serviceable. Please contact LYNX for repairs or to request an exchange unit. There is one consumable part used on this module which is the cooling fan. A service kit is available to exchange the fan.
Need help?
Do you have a question about the P DM 5240 D and is the answer not in the manual?
Questions and answers