Page 1
iCH Auto/English iCH Auto with Bluetooth CPAP System Instruction Manual...
Page 2
iCH Auto/English Table of Content English User’s manual..............P. 1...
Page 3
Auto/English Model No.: 9S-007301 Please read the instruction manual before use. IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING WARNING – THIS DEVICE IS NOT INTENDED FOR LIFE SUPPORT. It may stop operating due to power interruption without hazard to patient.
Page 4
iCH Auto/English iCH Auto/English Recommended separation distances between portable and mobile RF U.S. Federal law restricts this device to sale by or on the order of a licensed doctor. communications equipment and this device This device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
iCH Auto/English iCH Auto/English Guidance and Manufacturer’s Declaration- Electromagnetic Immunity: 1. Introduction This device is intended for use in the electromagnetic environment specified below. The user of this device should make sure it is used in such an environment. This manual should be used for initial set up of the system and saved for reference purpose. Immunity Test IEC60601 test Compliance...
iCH Auto/English iCH Auto/English Federal Communication Commission Interference Statement Power frequency 3 A/m 3 A/m Power frequency magnetic fields should be at levels (50/60Hz) magnetic characteristic of a typical location in a typical field commercial or hospital environment. This equipment has been tested and found to comply with the limits for a Class B digital device, IEC61000-4-8 pursuant to Part 15 of the FCC Rules.
iCH Auto/English iCH Auto/English EMC Warning Statement Appendix A: EMC Information Guidance and Manufacturer’s Declaration- Electromagnetic Emissions: This equipment has been tested and found to comply with the limits for medical devices to the IEC/EN 60601-1-2. These limits are designed to provide reasonable protection against harmful This device is intended for use in the electromagnetic environment specified below.
The iCH series systems are intended to provide safe and reliable operation according to the 2.1 Unpacking the Contents instructions provided by Apex Medical. Apex Medical recommends that the iCH system be inspected Components include: and serviced by authorized technicians if there is any sign of wear or concern with device function.
iCH Auto/English iCH Auto/English Symbols 3. Installation BF symbol, which indicated this product is according to the degree of protecting 3.1 Disassembling the Water Chamber against electric shock for type BF equipment. 1. Turn the device off and allow the heater and water to cool. If necessary, disconnect the flexible tubing from the water chamber.
iCH Auto/English iCH Auto/English 8. Technical Specifications 3.3 Setting Up 1. Place the device on a flat surface and at a lower level than your sleeping position. I t e m S p e c i f i c a t i o n s 2.
iCH Auto/English iCH Auto/English right. correctly. 4. Operation 3. Flexible tube is blocked. 3. Unblock the flexible tube. Condensation in mask or 1. The heater plate setting is too 1. Adjust the control knob to low flexible tube high. temperature setting. NOTE: Always read the operating instructions before use.
iCH Auto/English iCH Auto/English 4.2 Function Description NOTE: Please follow national requirements to dispose of the unit properly. Getting Started – First time use. For first-time use, follow the steps below: 6.4 Water Chamber 1. Make sure that your package contains a face or nasal mask with headgear. If not, your care Turn the heater off and allow the heater and water to cool.
iCH Auto/English iCH Auto/English (7) Compliance Information an authorized service agent. Do not drop any object into the air tube or air outlet. Hold "UP" and "DOWN" button to read compliance information while in the standby screen. Press “START/STANDBY” button to go back to standby screen 6.2 Tubing and Mask Period The tubing and mask should be checked and cleaned regularly.
iCH Auto/English iCH Auto/English 4.4 Flowchart of Menu settings 4.6 Using the heated humidifier Enter the user's menu mode by pressing the “MENU” button. 1. Turn the control knob on the back of the device to turn on the heater and the heater on indicator above the knob will light up (orange light), as shown in Figure 4-1 APAP Pressure Unit...
Need help?
Do you have a question about the 9S-007301 and is the answer not in the manual?
Questions and answers