impro IMPROX TT Installation Manual page 2

Twin antenna terminal
Table of Contents

Advertisement

Power Supply Combo (IPS910)
NOTE:
The Power Supply Combo includes a 3 A Switch Mode Power Supply which
provides power for the (optional) internal unit and for charging the (optional)
backup Battery. As the Power Supply Combo needs no more than 1 A, you
may power extra devices using up to 2 A continuous current from the
provided connector block. DO NOT exceed this 2 A limit on continuous
current draw. Devices with a high in-rush current demand, such as certain
maglocks and other electromechanical devices, can momentarily draw more
than 3 A. The Power Supply then effectively shuts down as directed by its
built in protection as exceeding the 3 A rating is considered a short-circuit.
Overcome this by installing the recommended 12 V 7 Ahr Battery to help
supplement the in-rush current such a device may draw on activation.
Power Input
Input Voltage .........................
Power Output
Output Voltage .......................
(Mains Power On)
Output Current ................
System Battery
Battery Type ...........................
Length ....................................
Width ......................................
Height .....................................
Charge Voltage ......................
The following specifications are common to all models of the ImproX TT:
Relays
Relay Output ..........................
Relay Contact Ratings ...........
Digital Inputs
Type ......................................
Protection Range ...................
XTT300-0-0-GB-16
Figure 1: End of Line (EOL) Sensing Circuit
January 2011
85 V AC to 265 V AC at 50/60 Hz.
13.8 V DC ±0.3 V DC.
2 A continuous (Power Output Terminals).
12 V 7 Ahr (Max) Sealed Lead Acid Battery.
151 mm (6 in) (Max).
65 mm (3 in) (Max).
99 mm (4 in) (Max) including the terminals.
13.8 V DC.
2 Independent, single-pole, double-throw
(SPDT) Relays, each with NO, COM and NC
contacts.
3 A at 24 V DC or 125 V AC.
1.5 A at 220 V AC.
4 Dry-contact Digital Inputs.
+50 V to -50 V continuous,
+80 V to -80 V surge.